Literature DB >> 28863982

Non-invasive pre-lens tear film assessment with high-speed videokeratoscopy.

Clara Llorens-Quintana1, Maryam Mousavi2, Dorota Szczesna-Iskander3, D Robert Iskander2.   

Abstract

PURPOSE: To evaluate the effect of two types of daily contact lenses (delefilcon A and omafilcon A) on the tear film and establish whether it is dependent on pre-corneal tear film characteristics using a new method to analyse high-speed videokeratoscopy recordings, as well as to determine the sensitivity of the method in differentiating between contact lens materials on eye.
METHODS: High-speed videokeratoscopy recordings were analysed using a custom made automated algorithm based on a fractal dimension approach that provides a set of parameters directly related to tear film stability. Fifty-four subjects participated in the study. Baseline measurements, in suppressed and natural blinking conditions, were taken before subjects were fitted with two different daily contact lenses and after four hours of contact lens wear.
RESULTS: The method for analysing the stability of the tear film provides alternative parameters to the non-invasive break up time to assess the quality of the pre-corneal and pre-lens tear film. Both contact lenses significantly decreased the quality of the tear film in suppressed and natural blinking conditions (p<0.001). The utilised method was able to distinguish between contact lens materials on eye in suppressed blinking conditions. The pre-corneal tear film characteristics were not correlated with the decrease in pre-lens tear film quality.
CONCLUSION: High-speed videokeratoscopy equipped with an automated method to analyse the dynamics of the tear film is able to distinguish between contact lens materials in vivo. Incorporating the assessment of pre-lens tear film to the clinical practice could aid improving contact lens fitting and understand contact lens comfort.
Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Contact lens materials; Non-invasive tear film assessment; Tear film kinetics

Mesh:

Year:  2017        PMID: 28863982     DOI: 10.1016/j.clae.2017.08.005

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  2 in total

1.  Tear Film Characteristics During Wear of Daily Disposable Contact Lenses.

Authors:  Giancarlo Montani; Maurizio Martino
Journal:  Clin Ophthalmol       Date:  2020-06-04

2.  Effects of Blink Rate on Tear Film Optical Quality Dynamics with Different Soft Contact Lenses.

Authors:  María García-Montero; Laura Rico-Del-Viejo; Irene Martínez-Alberquilla; Jose Luis Hernández-Verdejo; Amalia Lorente-Velázquez; David Madrid-Costa
Journal:  J Ophthalmol       Date:  2019-07-09       Impact factor: 1.909

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.