Literature DB >> 28862634

Artifact reduction in the CSPAD detectors used for LCLS experiments.

Alberto Pietrini1, Carl Nettelblad1.   

Abstract

The existence of noise and column-wise artifacts in the CSPAD-140K detector and in a module of the CSPAD-2.3M large camera, respectively, is reported for the L730 and L867 experiments performed at the CXI Instrument at the Linac Coherent Light Source (LCLS), in low-flux and low signal-to-noise ratio regime. Possible remedies are discussed and an additional step in the preprocessing of data is introduced, which consists of performing a median subtraction along the columns of the detector modules. Thus, we reduce the overall variation in the photon count distribution, lowering the mean false-positive photon detection rate by about 4% (from 5.57 × 10-5 to 5.32 × 10-5 photon counts pixel-1 frame-1 in L867, cxi86715) and 7% (from 1.70 × 10-3 to 1.58 × 10-3 photon counts pixel-1 frame-1 in L730, cxi73013), and the standard deviation in false-positive photon count per shot by 15% and 35%, while not making our average photon detection threshold more stringent. Such improvements in detector noise reduction and artifact removal constitute a step forward in the development of flash X-ray imaging techniques for high-resolution, low-signal and in serial nano-crystallography experiments at X-ray free-electron laser facilities.

Keywords:  CSPAD; CXI; LCLS; detector artifact

Year:  2017        PMID: 28862634     DOI: 10.1107/S160057751701058X

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  3 in total

1.  The ePix10k 2-megapixel hard X-ray detector at LCLS.

Authors:  Tim Brandt van Driel; Silke Nelson; Rebecca Armenta; Gabriel Blaj; Stephen Boo; Sébastien Boutet; Dionisio Doering; Angelo Dragone; Philip Hart; Gunther Haller; Christopher Kenney; Maciej Kwaitowski; Leo Manger; Mark McKelvey; Kaz Nakahara; Marco Oriunno; Takahiro Sato; Matt Weaver
Journal:  J Synchrotron Radiat       Date:  2020-04-17       Impact factor: 2.616

2.  Structure of the 30S ribosomal decoding complex at ambient temperature.

Authors:  E Han Dao; Frédéric Poitevin; Raymond G Sierra; Cornelius Gati; Yashas Rao; Halil Ibrahim Ciftci; Fulya Akşit; Alex McGurk; Trevor Obrinski; Paul Mgbam; Brandon Hayes; Casper De Lichtenberg; Fatima Pardo-Avila; Nicholas Corsepius; Lindsey Zhang; Matthew H Seaberg; Mark S Hunter; Mengling Liang; Jason E Koglin; Soichi Wakatsuki; Hasan Demirci
Journal:  RNA       Date:  2018-08-23       Impact factor: 4.942

3.  Aminoglycoside ribosome interactions reveal novel conformational states at ambient temperature.

Authors:  Mary E O'Sullivan; Frédéric Poitevin; Raymond G Sierra; Cornelius Gati; E Han Dao; Yashas Rao; Fulya Aksit; Halilibrahim Ciftci; Nicholas Corsepius; Robert Greenhouse; Brandon Hayes; Mark S Hunter; Mengling Liang; Alex McGurk; Paul Mbgam; Trevor Obrinsky; Fátima Pardo-Avila; Matthew H Seaberg; Alan G Cheng; Anthony J Ricci; Hasan DeMirci
Journal:  Nucleic Acids Res       Date:  2018-10-12       Impact factor: 16.971