Literature DB >> 28854784

Determination of Sulfonamides in Chicken Muscle by Pulsed Direct Current Electrospray Ionization Tandem Mass Spectrometry.

Xian Fu1,2, Hengxing Liang3, Bing Xia1, Chunyan Huang3, Baocheng Ji1,2, Yan Zhou1.   

Abstract

A simple and rapid approach for the simultaneous detection of trace amounts of six sulfonamides in chicken muscle was developed using pulsed direct current electrospray ionization tandem mass spectrometry (pulsed-dc ESI-MS/MS). The pretreatment of chicken muscle samples consisted of two steps: acetonitrile extraction and n-hexane delipidation. Sulfonamides do not need to be derivatized or chromatographed prior to pulsed-dc ESI-MS/MS. The factors affecting the performance of pulsed-dc ESI-MS/MS were studied. Under optimum conditions, the quantitative performance of pulsed-dc ESI-MS/MS was validated according to European Union Decision 2002/657/EC, and the sensitivity of pulsed-dc ESI-MS/MS was 3 times higher than that of ultrahigh-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The limits of detection obtained by pulsed-dc ESI-MS/MS were in the range of 0.07-0.11 μg/kg. The proposed method was simple, rapid, and sensitive, and was successfully used for quantitation and rapid screening of sulfonamides in real chicken muscle samples.

Entities:  

Keywords:  European Union Decision 2002/657/EC; UPLC-MS/MS; chicken muscle; pulsed-dc ESI-MS/MS; quantitation; rapid screening; sulfonamides

Mesh:

Substances:

Year:  2017        PMID: 28854784     DOI: 10.1021/acs.jafc.7b03803

Source DB:  PubMed          Journal:  J Agric Food Chem        ISSN: 0021-8561            Impact factor:   5.279


  3 in total

1.  Modifications of Au Nanoparticle-Functionalized Graphene for Sensitive Detection of Sulfanilamide.

Authors:  Bao-Shan He; Xiao-Hai Yan
Journal:  Sensors (Basel)       Date:  2018-03-13       Impact factor: 3.576

2.  Facile construction of magnetic core-shell covalent organic frameworks as efficient solid-phase extraction adsorbents for highly sensitive determination of sulfonamide residues against complex food sample matrices.

Authors:  Jing-Min Liu; Shi-Wen Lv; Xin-Yue Yuan; Hui-Lin Liu; Shuo Wang
Journal:  RSC Adv       Date:  2019-05-08       Impact factor: 4.036

3.  [Detection of drugs in urine by ambient direct ionization mass spectrometry].

Authors:  Shiling Xiong; Huanhuan Hong; Luhong Wen; Shundi Hu; Anqi Chen; Wei Xiong
Journal:  Se Pu       Date:  2022-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.