Literature DB >> 28853859

Metal Affinity-Enabled Capture and Release Antibody Reagents Generate a Multiplex Biomarker Enrichment System that Improves Detection Limits of Rapid Diagnostic Tests.

Westley S Bauer1, Christopher P Gulka1, Lidalee Silva-Baucage1, Nicholas M Adams2, Frederick R Haselton2, David W Wright1.   

Abstract

Multi-antigen rapid diagnostic tests (RDTs) are highly informative, simple, mobile, and inexpensive, making them valuable point-of-care (POC) diagnostic tools. However, these RDTs suffer from several technical limitations-the most significant being the failure to detect low levels of infection. To overcome this, we have developed a magnetic bead-based multiplex biomarker enrichment strategy that combines metal affinity and immunospecific capture to purify and enrich multiple target biomarkers. Modifying antibodies to contain histidine-rich peptides enables reversible loading onto immobilized metal affinity magnetic beads, generating a novel class of antibodies coined "Capture and Release" (CaR) antibody reagents. This approach extends the specificity of immunocapture to metal affinity magnetic beads while also maintaining a common trigger for releasing multiple biomarkers. Multiplex biomarker enrichment is accomplished by adding magnetic beads equipped with CaR antibody reagents to a large sample volume to capture biomarkers of interest. Once captured, these biomarkers are magnetically purified, concentrated, and released into a RDT-compatible volume. This system was tailored to enhance a popular dual-antigen lateral flow malaria RDT that targets Plasmodium falciparum histidine-rich protein-II (HRPII) and Plasmodium lactate dehydrogenase (pLDH). A suite of pLDH CaR antibody reagents were synthesized, characterized, and the optimal CaR antibody reagent was loaded onto magnetic beads to make a multiplex magnetic capture bead that simultaneously enriches pLDH and HRPII from Plasmodium falciparum parasitized blood samples. This system achieves a 17.5-fold improvement in the dual positive HRPII/pan-pLDH detection limits enabling visual detection of both antigens at levels correlating to 5 p/μL. This front-end sample processing system serves as an efficient strategy to improve the sensitivity of RDTs without the need for modifications or remanufacturing.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28853859     DOI: 10.1021/acs.analchem.7b01513

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

Review 1.  Inorganic Complexes and Metal-Based Nanomaterials for Infectious Disease Diagnostics.

Authors:  Christine F Markwalter; Andrew G Kantor; Carson P Moore; Kelly A Richardson; David W Wright
Journal:  Chem Rev       Date:  2018-12-04       Impact factor: 60.622

Review 2.  Multiplexed Immunosensors and Immunoarrays.

Authors:  Abby Jones; Lasangi Dhanapala; Rumasha N T Kankanamage; Challa V Kumar; James F Rusling
Journal:  Anal Chem       Date:  2019-12-02       Impact factor: 6.986

3.  Characterization and utility of immobilized metal affinity-functionalized cellulose membranes for point-of-care malaria diagnostics.

Authors:  Carson P Moore; Kristina Pieterson; Jenna M DeSousa; Lauren E Toote; David W Wright
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2021-11-03       Impact factor: 3.205

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.