BACKGROUND: Recent data suggest that the use of medium cut-off (MCO) dialyzers in hemodialysis (HD) promotes greater clearance and reduction ratio (RR) for myoglobin and other large-sized molecules than on-line hemodiafiltration (ol-HDF), but its effects on β2-microglobulin are not clear. We compared RR and clearances of small and middle-sized molecules between high-flux ol-HDF and MCO (Theranova) dialyzer in HD (MCO-HD) as well as nutritional parameters. MATERIALS AND METHODS: We retrospectively analyzed 10 patients treated first with ol-HDF who were thereafter switched to MCO-HD over a 1-year period. Three dialysis sessions in each 6-month period were examined. We calculated RR and clearance of small and middle-sized molecules. RESULTS: There was no significant difference between ol-HDF and MCO-HD for median serum albumin and prealbumin level, mean KT/V, mean urea and creatinine RR, mean β2-microglobulin (81 ± 5 vs. 81 ± 6%, p = 0.72) and myoglobin (60 ± 9% vs. 61 ± 7%, p = 0.59), RR or clearances. CONCLUSION: The use of MCO (Theranova) dialyzer in HD produces similar removal of urea, creatinine, β2-microglobulin and myoglobin as does ol-HDF, with good tolerance profile and without modification of nutritional status. .
BACKGROUND: Recent data suggest that the use of medium cut-off (MCO) dialyzers in hemodialysis (HD) promotes greater clearance and reduction ratio (RR) for myoglobin and other large-sized molecules than on-line hemodiafiltration (ol-HDF), but its effects on β2-microglobulin are not clear. We compared RR and clearances of small and middle-sized molecules between high-flux ol-HDF and MCO (Theranova) dialyzer in HD (MCO-HD) as well as nutritional parameters. MATERIALS AND METHODS: We retrospectively analyzed 10 patients treated first with ol-HDF who were thereafter switched to MCO-HD over a 1-year period. Three dialysis sessions in each 6-month period were examined. We calculated RR and clearance of small and middle-sized molecules. RESULTS: There was no significant difference between ol-HDF and MCO-HD for median serum albumin and prealbumin level, mean KT/V, mean urea and creatinine RR, mean β2-microglobulin (81 ± 5 vs. 81 ± 6%, p = 0.72) and myoglobin (60 ± 9% vs. 61 ± 7%, p = 0.59), RR or clearances. CONCLUSION: The use of MCO (Theranova) dialyzer in HD produces similar removal of urea, creatinine, β2-microglobulin and myoglobin as does ol-HDF, with good tolerance profile and without modification of nutritional status. .
Authors: Fernando Hadad-Arrascue; Lars-Göran Nilsson; Angela S Rivera; Angelito A Bernardo; Juan B Cabezuelo Romero Journal: Ther Apher Dial Date: 2021-06-29 Impact factor: 2.195
Authors: Daniel E Weiner; Luke Falzon; Line Skoufos; Angelito Bernardo; Werner Beck; Mengqi Xiao; Ha Tran Journal: Clin J Am Soc Nephrol Date: 2020-08-25 Impact factor: 8.237