Literature DB >> 28853192

Resection accuracy of patient-specific cutting guides in total knee replacement.

Gregory C Wernecke1, Scott Taylor1, Penny Wernecke1, Samuel J MacDessi1, Darren B Chen1.   

Abstract

BACKGROUND: Patient-specific guides (PSGs) have been thoroughly investigated with regards to reconstitution of mechanical alignment in total knee arthroplasty (TKA). The ability to replicate the preoperative surgical plan is essential for optimal outcomes but intraoperative measurements to confirm accurate progression through the operation are limited. This leads to our clinical question: can PSGs replicate the planned bone resection depth during TKA?
METHODS: This is a prospective case series of 118 patients who underwent TKA using magnetic resonance imaging-based patient-specific cutting guides. Intraoperative bone resection thickness was measured and compared with the preoperative planned bone resections as a primary outcome. Secondary outcomes included the need for additional bone resections, the number of cases for which the PSG technique was abandoned, final component sizes and mechanical alignment.
RESULTS: PSGs could not accurately recreate preoperative plan. PSGs resulted in over-resection in all bone cuts compared with the preoperative surgical resection plan. Secondary osteotomies were required in 37% of patients. PSGs had to be abandoned in 10.5% of cases, mostly due to suboptimal fit of the femoral block. The tibial component size was altered more frequently than the femoral.
CONCLUSION: Intraoperatively, PSGs could not accurately recreate the preoperative plan. PSGs are marketed as user-friendly tools to simplify TKA but our research demonstrates the need for surgeons to monitor surgical progression and compensate for errors occurring during the use of PSGs.
© 2017 Royal Australasian College of Surgeons.

Entities:  

Keywords:  computer-assisted surgery; knee joint; knee replacement arthroplasty; osteoarthritis

Mesh:

Year:  2017        PMID: 28853192     DOI: 10.1111/ans.14143

Source DB:  PubMed          Journal:  ANZ J Surg        ISSN: 1445-1433            Impact factor:   1.872


  3 in total

1.  Evaluation of the accuracy of resected bone thickness based on patient-specific instrumentation during total knee arthroplasty.

Authors:  Kazumasa Yamamura; Fumiaki Inori; Sadahiko Konishi
Journal:  Arch Orthop Trauma Surg       Date:  2021-02-06       Impact factor: 3.067

2.  Conventional instruments are more accurate for measuring the depth of the tibial cut than computer-assisted surgery in total knee arthroplasty: a prospective study.

Authors:  Antonio Klasan; Sven Edward Putnis; Samuel Grasso; Thomas Neri; Myles Raphael Coolican
Journal:  Arch Orthop Trauma Surg       Date:  2020-03-07       Impact factor: 3.067

3.  The Bony Resection Accuracy with Patient-Specific Instruments during Total Knee Arthroplasty: A Retrospective Case Series Study.

Authors:  Liang Yuan; Bin Yang; Xiaohua Wang; Bin Sun; Ke Zhang; Yichen Yan; Jie Liu; Jie Yao
Journal:  Biomed Res Int       Date:  2021-02-15       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.