Literature DB >> 28846143

Characterization of a stepwise approach in cavotricuspid isthmus ablation for typical atrial flutter: A randomized study comparing three catheters.

José Manuel Rubín1, David Calvo1, Diego Pérez1, Ana Fidalgo1, Jesús María de la Hera1, Lidia Martínez1, Esmeralda Capín1, Haritz Arrizabalaga1, Lidia Carballeira1, Daniel García1, Cesar Morís1.   

Abstract

INTRODUCTION: Our aim was to characterize a stepwise approach in cavotricuspid isthmus ablation for typical atrial flutter in a prospective, noncrossover randomized study.
METHODS: One hundred and fifty patients referred for cavotricuspid isthmus (CTI)-dependent atrial flutter ablation were randomized to undergo an ablation with an 8-mm-tip catheter (group 1), a 3.5-mm open irrigation-tip catheter (group 2), and a 3.5-mm open irrigation porous-tip catheter (group 3). A stepwise approach was performed, changing the ablation site from medial to septal aspects of the CTI, in case it was not effective without crossover between catheters.
RESULTS: CTI block was achieved in all the patients using only one catheter. There was a 68% efficacy in group 1, 40% in group 2, and 28% in group 3 to achieve CTI block within 10 minutes (P  =  0.001) and 96%, 70%, and 70% in groups 1, 2, and 3, respectively, within 20 minutes (P  =  0.002) of radiofrequency ablation. The 8-mm catheter was also faster in fluoroscopy time and CTI block time. There were no differences in efficiency in the both irrigated catheters. There were no significant differences in complications among three catheters.
CONCLUSIONS: With this stepwise approach, it is possible to achieve CTI block in all cases, using a single catheter without crossover, with good times of procedure and with a low complication rate. The 8-mm solid catheter is faster than the other irrigated-tip catheters. The 3.5-mm open irrigation porous-tip catheter is as effective and safe as the conventional irrigated-tip catheter.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  atrial flutter; catheter ablation; irrigated-tip catheter; isthmus block; radiofrequency

Mesh:

Year:  2017        PMID: 28846143     DOI: 10.1111/pace.13170

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

1.  Contemporary Yield of 24-hour Holter Monitoring: Role of Inter-Atrial Block Recognition.

Authors:  Victor Bazan; German Cediel; Cinta Llibre; Axel Sarrias; Isabel Romeo; Sònia Ibars; Francisco Escudero; Sandra Valdivielso; Felipe Bisbal; Roger Villuendas; Antoni Bayes-Genis; Ferran Padilla
Journal:  J Atr Fibrillation       Date:  2019-08-31

2.  Ultralow temperature cryoablation using near-critical nitrogen for cavotricuspid isthmus-ablation, first-in-human results.

Authors:  Martijn N Klaver; Tom J R De Potter; Konstantinos Iliodromitis; Alexander Babkin; David Cabrita; Davide Fabbricatore; Lucas V A Boersma
Journal:  J Cardiovasc Electrophysiol       Date:  2021-07-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.