Literature DB >> 28845000

[Application of transcription mediated amplification and real-time reverse transcription polymerase chain reaction in detection of human immunodeficiency virus RNA].

Daxian Wu1, Shuhui Tao2, Shuiping Liu3, Jiebin Zhou2, Deming Tan2, Zhouhua Hou2.   

Abstract

OBJECTIVE: To observe the sensitivity of transcription mediated amplification (TMA), and to compare its performance with real-time reverse transcription polymerase chain reaction (real-time RT-PCR) in detecting human immunodeficiency virus RNA (HIV RNA).

Methods: TMA system was established with TaqMan probes, specific primers, moloney murine leukemia virus (MMLV) reverse transcriptase, T7 RNA polymerase, and reaction substrates. The sensitivity of TMA was evaluated by amplifying a group of 10-fold diluted HIV RNA standards which were transcribed in vitro. A total of 60 plasma of HIV infected patients were measured by TMA and Cobas Amplicor HIV-1 Monitor test to observe the positive rate. The correlation and concordance of the above two technologies were investigated by linear regression and Bland-Altman analysis.

Results: TMA system was established successfully and HIV RNA transcribed standards at concentration of equal or more than 10 copies/mL could be detected by TMA technology. Among 60 samples of plasma from HIV infected patients, 46 were positively detected and 12 were negatively amplified by both TMA and Cobas reagents; 2 samples were positively tested by Cobas reagent but negatively tested by TMA system. The concordance rate of the two methods was 97.1% and the difference of positive detection rate between the two methods was not statistically significant (P>0.05). Linear regression was used for 46 samples which were positively detected by both TMA and Cobas reagents and showed an excellent correlation between the two reagents (r=0.997, P<0.001). Bland-Altma analysis revealed that the mean different value of HIV RNA levels for denary logarithm was 0.02. Forty-four samples were included in 95% of credibility interval of concordance.

Conclusion: TMA system has the potential of high sensitivity. TMA and real-time RT-PCR keep an excellent correlation and consistency in detecting HIV RNA.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28845000     DOI: 10.11817/j.issn.1672-7347.2017.07.006

Source DB:  PubMed          Journal:  Zhong Nan Da Xue Xue Bao Yi Xue Ban        ISSN: 1672-7347


  1 in total

Review 1.  Trends in MERS-CoV, SARS-CoV, and SARS-CoV-2 (COVID-19) Diagnosis Strategies: A Patent Review.

Authors:  José Adão Carvalho Nascimento Junior; Anamaria Mendonça Santos; Ana Maria Santos Oliveira; Adriana Gibara Guimarães; Lucindo José Quintans-Júnior; Henrique Douglas Melo Coutinho; Natália Martins; Lysandro Pinto Borges; Mairim Russo Serafini
Journal:  Front Public Health       Date:  2020-10-27
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.