BACKGROUND: Transcatheter aortic valve replacement (TAVR) is often associated with intraventricular conduction disturbances. We aimed to determine the association between implantation depth assessed by multidetector computed tomography (MDCT) and new-onset conduction abnormalities after TAVR. METHODS: Retrospective single-center study including patients consecutively submitted to TAVR, between August/2007 and October/2016, who underwent routine MDCT 3 months after the procedure. The endpoint of conduction disturbances included permanent pacemaker implantation and/or new-onset left bundle-branch block. Implantation depth was determined as the distance between the ventricular end of the prothesis and the native ring, at the level of the non-coronary cusp. RESULTS: 138 patients were included (female gender 52.2%, mean age 78.7 ± 6.9 years). The EuroSCORE II was 4.0 ± 3.9% and 57.2% were treated with self-expanding prosthesis. The endpoint of conduction abnormalities was found in 45.7% (n = 63). The implantation depth was greater in the group with conduction disturbances (7.7 vs 6.4 mm, p = 0.006). Chronic obstructive pulmonary disease, oversizing and implantation depth were independent predictors of conduction abnormalities. Implantation depth had an AUC of 0.64 (p = 0.004) for the prediction of conduction abnormalities and a cut-off value of 7.1 mm predicted the composed endpoint with a sensitivity and specificity of 65% and 70%, respectively. CONCLUSIONS: Implantation depth assessed by MDCT is associated with new-onset conduction disturbances after TAVR. In patients with conduction abnormalities, which do not qualify for the immediate implantation of pacemaker, the assessment of implantation depth by MDCT may be an additional marker of risk to aid decision-making.
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is often associated with intraventricular conduction disturbances. We aimed to determine the association between implantation depth assessed by multidetector computed tomography (MDCT) and new-onset conduction abnormalities after TAVR. METHODS: Retrospective single-center study including patients consecutively submitted to TAVR, between August/2007 and October/2016, who underwent routine MDCT 3 months after the procedure. The endpoint of conduction disturbances included permanent pacemaker implantation and/or new-onset left bundle-branch block. Implantation depth was determined as the distance between the ventricular end of the prothesis and the native ring, at the level of the non-coronary cusp. RESULTS: 138 patients were included (female gender 52.2%, mean age 78.7 ± 6.9 years). The EuroSCORE II was 4.0 ± 3.9% and 57.2% were treated with self-expanding prosthesis. The endpoint of conduction abnormalities was found in 45.7% (n = 63). The implantation depth was greater in the group with conduction disturbances (7.7 vs 6.4 mm, p = 0.006). Chronic obstructive pulmonary disease, oversizing and implantation depth were independent predictors of conduction abnormalities. Implantation depth had an AUC of 0.64 (p = 0.004) for the prediction of conduction abnormalities and a cut-off value of 7.1 mm predicted the composed endpoint with a sensitivity and specificity of 65% and 70%, respectively. CONCLUSIONS: Implantation depth assessed by MDCT is associated with new-onset conduction disturbances after TAVR. In patients with conduction abnormalities, which do not qualify for the immediate implantation of pacemaker, the assessment of implantation depth by MDCT may be an additional marker of risk to aid decision-making.
Authors: Giorgia Rocatello; Nahid El Faquir; Ole de Backer; Martin J Swaans; Azeem Latib; Luca Vicentini; Patrick Segers; Matthieu De Beule; Peter de Jaegere; Peter Mortier Journal: J Cardiovasc Transl Res Date: 2019-08-23 Impact factor: 4.132
Authors: Philipp Breitbart; Martin Czerny; Jan Minners; Holger Schröfel; Franz-Josef Neumann; Philipp Ruile Journal: J Clin Med Date: 2022-04-18 Impact factor: 4.964
Authors: Ghazaleh Haghiashtiani; Kaiyan Qiu; Jorge D Zhingre Sanchez; Zachary J Fuenning; Priya Nair; Sarah E Ahlberg; Paul A Iaizzo; Michael C McAlpine Journal: Sci Adv Date: 2020-08-28 Impact factor: 14.136