Literature DB >> 28844301

Electrophoretic deposition of graphene oxide onto carbon fibers for in-tube solid-phase microextraction.

Juanjuan Feng1, Xiuqin Wang1, Yu Tian1, Yanan Bu1, Chuannan Luo1, Min Sun2.   

Abstract

Carbon fibers (CFs) were functionalized with graphene oxide (GO) by an electrophoretic deposition (EPD) method for in-tube solid-phase microextraction (SPME). GO-CFs were filled into a poly(ether ether ketone) (PEEK) tube to obtain a fibers-in-tube SPME device, which was connected with high performance liquid chromatography (HPLC) equipment to build online SPME-HPLC system. Compared with CFs, GO-CFs presented obviously better extraction performance, due to excellent adsorption property and large surface area of GO. Using ten polycyclic aromatic hydrocarbons (PAHs) as model analytes, the important extraction conditions were optimized, such as sample flow rate, extraction time, organic solvent content and desorption time. An online analysis method was established with wide linear range (0.01-50μgL-1) and low detection limits (0.001-0.004μgL-1). Good sensitivity resulted from high enrichment factors (1133-3840) of GO-CFs in-tube device towards PAHs. The analysis method was used to online determination of PAHs in wastewater samples. Some target analytes were detected and relative recoveries were in the range of 90.2-112%. It is obvious that the proposed GO-CFs in-tube device was an efficient extraction device, and EPD could be used to develop nanomaterials functionalized sorbents for sample preparation.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Carbon fibers; Electrophoretic deposition; Graphene oxide; High performance liquid chromatography; Polycyclic aromatic hydrocarbons; Solid-phase microextraction

Mesh:

Substances:

Year:  2017        PMID: 28844301     DOI: 10.1016/j.chroma.2017.07.086

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Ordered macro/micro-porous metal-organic framework of type ZIF-8 in a steel fiber as a sorbent for solid-phase microextraction of BTEX.

Authors:  Fernando Maya; Milad Ghani
Journal:  Mikrochim Acta       Date:  2019-06-11       Impact factor: 5.833

Review 2.  Bioanalytical HPLC Applications of In-Tube Solid Phase Microextraction: A Two-Decade Overview.

Authors:  Natalia Manousi; Paraskevas D Tzanavaras; Constantinos K Zacharis
Journal:  Molecules       Date:  2020-04-30       Impact factor: 4.411

3.  Application of Covalent Organic Porous Polymers-Functionalized Basalt Fibers for in-Tube Solid-Phase Microextraction.

Authors:  Qiong Jiang; Peng Xu; Juanjuan Feng; Min Sun
Journal:  Molecules       Date:  2020-12-08       Impact factor: 4.411

4.  [Recent advance of new sample preparation materials in the analysis and detection of environmental pollutants].

Authors:  Juanjuan Feng; Xiangping Ji; Chunying Li; Mingxia Sun; Sen Han; Jiaqing Feng; Haili Sun; Yang Feng; Min Sun
Journal:  Se Pu       Date:  2021-08
  4 in total