Literature DB >> 28843984

Arteriovenous Fistulae for Haemodialysis: A Systematic Review and Meta-analysis of Efficacy and Safety Outcomes.

L C Bylsma1, S M Gage2, H Reichert1, S L M Dahl2, J H Lawson3.   

Abstract

BACKGROUND: Arteriovenous fistulae are the currently recommended gold standard vascular access modality for haemodialysis because of their prolonged patency, improved durability, and low risk of infection for those that mature. However, notable disadvantages are observed in terms of protracted maturation time, associated high rates of catheter use, and substantial abandonment rates. The aim of this study was to quantitatively summarize the outcomes of fistula patency, infection, maturation, and abandonment published in the scientific literature.
METHODS: This was a systematic review and meta-analyses of studies evaluating fistula outcomes. Literature searches were conducted in multiple databases to identify observational and interventional studies of mean fistula patency rates at 1 year, infection risk, maturation time, and abandonment. Digitisation software was used to simulate individual patient level data from Kaplan-Meier survival plots.
RESULTS: Over 8000 studies were reviewed, and from these, 318 studies were included comprising 62,712 accesses. For fistulas the primary unassisted, primary assisted, and secondary patency rates at one year were 64%, 73% and 79% respectively, however not all fistulas reported as patent could be confirmed as being clinically useful for dialysis (i.e. functional patency). For fistulas that were reported as mature, mean time to maturation was 3.5 months, however only 26% of created fistulas were reported as mature at 6 months and 21% of fistulas were abandoned without use. Overall risk of infection in fistula patients was 4.1% and the overall rate per 100 access days was 0.018.
CONCLUSIONS: Reported fistula patency rates may overstate their potential clinical utility when time to maturation, maturation rate, abandonment and infection are considered. Protracted maturation times, abandonment and infection all have a significant impact on evaluating the clinical utility of fistula creation. A rigorous and consistent set of outcomes definitions for hemodialysis access are necessary to clarify factors contributing to fistula success and the clinical consequence of fistula failure.
Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Arteriovenous fistula; Haemodialysis; Maturation; Meta-analysis; Patency

Mesh:

Year:  2017        PMID: 28843984     DOI: 10.1016/j.ejvs.2017.06.024

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  31 in total

1.  Patency Outcomes of Arteriovenous Fistulas and Grafts for Hemodialysis Access: A Trade-Off between Nonmaturation and Long-Term Complications.

Authors:  Bram M Voorzaat; Cynthia J Janmaat; Koen E A van der Bogt; Friedo W Dekker; Joris I Rotmans
Journal:  Kidney360       Date:  2020-07-23

Review 2.  Patency of ePTFE Arteriovenous Graft Placements in Hemodialysis Patients: Systematic Literature Review and Meta-Analysis.

Authors:  Ronald J Halbert; Gina Nicholson; Robert J Nordyke; Alison Pilgrim; Laura Niklason
Journal:  Kidney360       Date:  2020-10-15

3.  Predictors of Arteriovenous Fistula Failure: A Post Hoc Analysis of the FAVOURED Study.

Authors:  Yong Pey See; Yeoungjee Cho; Elaine M Pascoe; Alan Cass; Ashley Irish; David Voss; Kevan R Polkinghorne; Lai Seong Hooi; Loke-Meng Ong; Peta-Anne Paul-Brent; Peter G Kerr; Trevor A Mori; Carmel M Hawley; David W Johnson; Andrea K Viecelli
Journal:  Kidney360       Date:  2020-09-14

4.  Plasmatic osteopontin and vascular access dysfunction in hemodialysis patients: a cross-sectional, case-control study (The OSMOSIS Study).

Authors:  Julie Contenti; Matthieu Durand; Sandor Vido; Serge Declemy; Juliette Raffort; Joseph Carboni; Sophie Bonnet; Christophe Koelsch; Réda Hassen-Khodja; Philippe Gual; Nathalie M Mazure; Nirvana Sadaghianloo
Journal:  J Nephrol       Date:  2021-09-01       Impact factor: 3.902

5.  Erroneous measurement of hematocrit from arterial cannula on failed fistula limb site in renal transplant recipient: A cautious path to tread!

Authors:  Heena Garg; Indira Gurajala; Padmaja Durga
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2021-12-16

Review 6.  Challenges and novel therapies for vascular access in haemodialysis.

Authors:  Jeffrey H Lawson; Laura E Niklason; Prabir Roy-Chaudhury
Journal:  Nat Rev Nephrol       Date:  2020-08-24       Impact factor: 28.314

7.  Serum levels of the endothelial glycocalyx constituents and the early failure of forearm autologous arteriovenous fistulas in end-stage renal disease patients: a prospective cohort study.

Authors:  Xianglei Kong; Jing Du; Hong Su; Qinlan Chen; Lijun Tang; Lei Zhang; Zunsong Wang; Liming Liang; Dongmei Xu
Journal:  Int Urol Nephrol       Date:  2019-10-30       Impact factor: 2.370

Review 8.  Sterile inflammation in the pathogenesis of maturation failure of arteriovenous fistula.

Authors:  Megan Nguyen; Finosh G Thankam; Devendra K Agrawal
Journal:  J Mol Med (Berl)       Date:  2021-03-05       Impact factor: 4.599

9.  Integrated management to reduce fistula-related long-term complications and improve the quality of life after arteriovenous fistula surgery: A retrospective cohort study.

Authors:  Min Ning; Dan Luo; Gang Ye; Ting Zhang; Li Liu; Fumei Peng
Journal:  Nurs Open       Date:  2021-03-04

10.  Outcomes of arteriovenous access among cancer patients requiring chronic haemodialysis.

Authors:  Seonjeong Jeong; Hyunwook Kwon; Jai Won Chang; Youngjin Han; Tae-Won Kwon; Yong-Pil Cho
Journal:  BMC Nephrol       Date:  2020-07-23       Impact factor: 2.388

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.