Literature DB >> 28841123

Optic neuropathy after anterior communicating artery aneurysm clipping: 3 cases and techniques to address a correctable pitfall.

Joseph R Linzey1, Kevin S Chen2, Luis Savastano2, B Gregory Thompson2, Aditya S Pandey2.   

Abstract

Brain shifts following microsurgical clip ligation of anterior communicating artery (ACoA) aneurysms can lead to mechanical compression of the optic nerve by the clip. Recognition of this condition and early repositioning of clips can lead to reversal of vision loss. The authors identified 3 patients with an afferent pupillary defect following microsurgical clipping of ACoA aneurysms. Different treatment options were used for each patient. All patients underwent reexploration, and the aneurysm clips were repositioned to prevent clip-related compression of the optic nerve. Near-complete restoration of vision was achieved at the last clinic follow-up visit in all 3 patients. Clip ligation of ACoA aneurysms has the potential to cause clip-related compression of the optic nerve. Postoperative visual examination is of utmost importance, and if any changes are discovered, reexploration should be considered as repositioning of the clips may lead to resolution of visual deterioration.

Entities:  

Keywords:  ACoA = anterior communicating artery; APD = afferent pupillary defect; CON = compressive optic neuropathy; SAH = subarachnoid hemorrhage; WFNS = World Federation of Neurosurgical Societies; afferent pupillary defect; anterior communicating artery aneurysm; intracranial aneurysm; optic nerve injuries; surgical clips; vascular disorders

Mesh:

Year:  2017        PMID: 28841123     DOI: 10.3171/2017.2.JNS162654

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  1 in total

1.  Microsurgical Clip Suspension to Prevent Optic Neuropathy Following Ligation of Anterior Communicating Artery Aneurysm: A Technical Report and Surgical Video.

Authors:  Douglas J Chung; Alejandro Matus; Vitaly Siomin
Journal:  Cureus       Date:  2019-12-11
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.