Literature DB >> 28836515

Endoscopic ultrasound-guided antegrade metal stent placement using the stent-in-stent technique in a patient with malignant hilar biliary obstruction.

Hiroshi Yamauchi1, Mitsuhiro Kida1, Shiro Miyazawa1, Kosuke Okuwaki1, Tomohisa Iwai1, Hiroshi Imaizumi1, Wasaburo Koizumi1.   

Abstract

Entities:  

Year:  2018        PMID: 28836515      PMCID: PMC6032706          DOI: 10.4103/eus.eus_19_17

Source DB:  PubMed          Journal:  Endosc Ultrasound        ISSN: 2226-7190            Impact factor:   5.628


× No keyword cloud information.
We report a case of a 45-year-old male who underwent a right lobectomy for metastatic liver tumors from colorectal cancer. Nine years after surgery, the patient had obstructive jaundice (total bilirubin - 19.1 mg/dL and direct bilirubin - 14.6 mg/dL). Magnetic resonance imaging showed a high-intensity mass at the porta hepatis on diffusion-weighted images. Three-dimensional magnetic resonance cholangiopancreatography and true fast imaging with steady precession showed that the B2, B3, and B4 segments were displaced [Figure 1a–c]. A malignant hilar biliary obstruction caused by recurrence of liver metastasis was diagnosed.
Figure 1

(a) A diffusion-weighted magnetic resonance imaging showed a high-intensity mass at the porta hepatis. (b) True fast imaging with steady precession showed a high-intensity mass at the porta hepatis and left lobe of liver had hepatomegaly in compensatory. (c) Three-dimensional magnetic resonance cholangiopancreatography showed the B2, B3, and B4 segments were displaced

(a) A diffusion-weighted magnetic resonance imaging showed a high-intensity mass at the porta hepatis. (b) True fast imaging with steady precession showed a high-intensity mass at the porta hepatis and left lobe of liver had hepatomegaly in compensatory. (c) Three-dimensional magnetic resonance cholangiopancreatography showed the B2, B3, and B4 segments were displaced Endoscopic ultrasound-guided biliary drainage (EUS-BD) was performed because the duodenum was deformed due to operation and a duodenoscope could not reach the papilla of Vater. EUS showed the B2 and B3 dilatation and tumor at the porta hepatis [Figure 2a]. At first, the B2 segment was punctured [Figure 2b and 2c] because the liver volume of Segment 2 (55% [1089 mL] of total liver volume) was larger than Segment 3 (35% [693 mL]). A self-expanding metal stent ([SEMS] Zilver 635®, 8-mm, 6-French, Cook Medical, Bloomington, USA) was placed in the stricture site [Video 1 and Figure 2b and 2c]. Because there was a high risk of transesophageal and transmediastinal puncture, hepaticogastrostomy (HGS) was not performed.
Figure 2

(a) Endoscopic ultrasound showed the dilation of B2 segment and B3 segment due to the recurrence of liver metastasis at the porta hepatis. (b) The B2 segment was punctured under endoscopic ultrasound guidance, and cholangiography showed a dilation of B2. (c) A self-expanding metal stent was placed in the stricture site

(a) Endoscopic ultrasound showed the dilation of B2 segment and B3 segment due to the recurrence of liver metastasis at the porta hepatis. (b) The B2 segment was punctured under endoscopic ultrasound guidance, and cholangiography showed a dilation of B2. (c) A self-expanding metal stent was placed in the stricture site Five days after the first procedure, serum bilirubin level was not enough to improve (total bilirubin - 9.8 mg/dL). EUS showed the dilation of the B3 [Figure 3a], and the B3 was punctured transgastrically [Figure 3b]. An SEMS was placed in the stricture site of B3 using stent-in-stent technique [Figure 3c]. Because of the transgastric puncture, HGS was performed using a 7-French plastic stent to secure an access route at the time of reintervention [Video 2 and Figure 4a]. Five days after the second procedure, serum bilirubin level was improved (total bilirubin - 3.2 mg/dL). There were no procedural complications. Stent dysfunction did not occur before the patient died of cancer (during 128 days) [Figure 4b].
Figure 3

(a) Endoscopic ultrasound showed the dilation of B3 segment due to the recurrence of liver metastasis at the porta hepatis and a SEMS of B2 segment. (b) The B3 segment was punctured under endoscopic ultrasound guidance, and cholangiography showed a dilation of B3. (c) A self-expanding metal stent was placed in the stricture site using stent-in-stent technique

Figure 4

(a) After 3 months of procedures, there was no stent dislocation. (b) After 3 months of procedure, computed tomography showed self-expanding metal stents and no dilation of B2 and B3

(a) Endoscopic ultrasound showed the dilation of B3 segment due to the recurrence of liver metastasis at the porta hepatis and a SEMS of B2 segment. (b) The B3 segment was punctured under endoscopic ultrasound guidance, and cholangiography showed a dilation of B3. (c) A self-expanding metal stent was placed in the stricture site using stent-in-stent technique (a) After 3 months of procedures, there was no stent dislocation. (b) After 3 months of procedure, computed tomography showed self-expanding metal stents and no dilation of B2 and B3

DISCUSSION AND CONCLUSION

In patients in whom a transpapillary biliary drainage is difficult, percutaneous transhepatic biliary drainage (PTBD) will be an effective procedure. However, the PTBD will be difficult to perform for B2 segment and compromise the quality of life of patients, especially in case of multiple PTBD was needed like this patient's condition. In recent years, EUS-BD has been actively performed, and EUS-guided antegrade-biliary-stenting (EUS-AS) has also been reported to be an effective procedure.[123] Moreover, EUS-HGS combined with AS was reported to safely and effectively avoid adverse events associated with EUS-HGS.[2] Sometimes, EUS-BD is challenging in patients with malignant hilar biliary obstruction. However, EUS-AS using the stent-in-stent technique and HGS may be a useful procedure for the treatment of malignant hilar biliary obstruction (B2 and B3 was displaced) that is difficult to manage by transpapillary procedures.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  3 in total

1.  Multicenter study on endoscopic ultrasound-guided expandable biliary metal stent placement: choice of access route, direction of stent insertion, and drainage route.

Authors:  Vinay Dhir; Everson L A Artifon; Kapil Gupta; Juan J Vila; Roberta Maselli; Mariana Frazao; Amit Maydeo
Journal:  Dig Endosc       Date:  2013-08-13       Impact factor: 7.559

2.  Endoscopic ultrasound (EUS)-guided transhepatic anterograde self-expandable metal stent (SEMS) placement across malignant biliary obstruction.

Authors:  T Nguyen-Tang; K F Binmoeller; A Sanchez-Yague; J N Shah
Journal:  Endoscopy       Date:  2010-01-29       Impact factor: 10.093

3.  EUS-guided hepaticogastrostomy combined with fine-gauge antegrade stenting: a pilot study.

Authors:  Takeshi Ogura; Daisuke Masuda; Akira Imoto; Toshihisa Takeushi; Rieko Kamiyama; Malak Mohamed; Eiji Umegaki; Kazuhide Higuchi
Journal:  Endoscopy       Date:  2014-02-26       Impact factor: 10.093

  3 in total
  1 in total

1.  Endoscopic Ultrasound-guided Gastroenterostomy: A Promising Alternative to Surgery.

Authors:  Guoxin Wang; Xiang Liu; Sheng Wang; Nan Ge; Jintao Guo; Siyu Sun
Journal:  J Transl Int Med       Date:  2019-10-12
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.