Kyeongmin Jang1, Hack-Lyoung Kim2, Miri Park1, Sohee Oh3, So Won Oh4, Woo-Hyun Lim2, Jae-Bin Seo2, Sang-Hyun Kim2, Joo-Hee Zo2, Myung-A Kim2. 1. Department of Nursing, Boramae Medical Center. 2. Division of Cardiology, Boramae Medical Center, Seoul National University College of Medicine. 3. Department of Biostatistics, Boramae Medical Center. 4. Department of Nuclear Medicine, Boramae Medical Center, Seoul National University College of Medicine.
Abstract
AIM: The aim of this study was to investigate whether information on arterial stiffness can improve the value of single-photon emission computed tomography (SPECT) in the detection of obstructive coronary artery disease (CAD). METHODS: A total of 233 patients (age: 62.2±10.8 years, 60.3% males) with detected ischemia on SPECT undergoing invasive coronary angiography (ICA) and brachial-ankle pulse wave velocity (baPWV) measurement within a month was retrospectively reviewed. RESULTS: Of the 233 patients, 190 (81.5%) had obstructive CAD (≥50% luminal stenosis). The difference in baPWV according to the presence of obstructive CAD was significant in patients in the mild ischemia group [summed stress score (SSS): 4-8] (1,770±364 cm versus 1,490±328 cm, p<0.001) but not in the moderate (SSS: 9-13) or severe (SSS: ≥14) ischemia groups (p>0.05 for each). Receiver operating characteristic curve analyses showed that the diagnostic value of baPWV for obstructive CAD was significant only in patients in the mild ischemia group (area under curve: 0.714; p=0.001) but not in the moderate or severe ischemia groups (p>0.05 for each). Adding information on baPWV to SPECT results and clinical parameters significantly increased diagnostic accuracy in the detection of obstructive CAD in patients with mild ischemia (integrated discrimination improvement p=0.006) but not in those with moderate or severe ischemia on SPECT (p>0.05 for each). CONCLUSIONS: The results of this study suggest that baPWV may have additional value to SPECT for the detection of obstructive CAD, especially in patients with mild ischemia on SPECT.
AIM: The aim of this study was to investigate whether information on arterial stiffness can improve the value of single-photon emission computed tomography (SPECT) in the detection of obstructive coronary artery disease (CAD). METHODS: A total of 233 patients (age: 62.2±10.8 years, 60.3% males) with detected ischemia on SPECT undergoing invasive coronary angiography (ICA) and brachial-ankle pulse wave velocity (baPWV) measurement within a month was retrospectively reviewed. RESULTS: Of the 233 patients, 190 (81.5%) had obstructive CAD (≥50% luminal stenosis). The difference in baPWV according to the presence of obstructive CAD was significant in patients in the mild ischemia group [summed stress score (SSS): 4-8] (1,770±364 cm versus 1,490±328 cm, p<0.001) but not in the moderate (SSS: 9-13) or severe (SSS: ≥14) ischemia groups (p>0.05 for each). Receiver operating characteristic curve analyses showed that the diagnostic value of baPWV for obstructive CAD was significant only in patients in the mild ischemia group (area under curve: 0.714; p=0.001) but not in the moderate or severe ischemia groups (p>0.05 for each). Adding information on baPWV to SPECT results and clinical parameters significantly increased diagnostic accuracy in the detection of obstructive CAD in patients with mild ischemia (integrated discrimination improvement p=0.006) but not in those with moderate or severe ischemia on SPECT (p>0.05 for each). CONCLUSIONS: The results of this study suggest that baPWV may have additional value to SPECT for the detection of obstructive CAD, especially in patients with mild ischemia on SPECT.
Authors: Glenn N Levine; Eric R Bates; James C Blankenship; Steven R Bailey; John A Bittl; Bojan Cercek; Charles E Chambers; Stephen G Ellis; Robert A Guyton; Steven M Hollenberg; Umesh N Khot; Richard A Lange; Laura Mauri; Roxana Mehran; Issam D Moussa; Debabrata Mukherjee; Brahmajee K Nallamothu; Henry H Ting Journal: J Am Coll Cardiol Date: 2011-11-07 Impact factor: 24.094
Authors: S R Underwood; C Anagnostopoulos; M Cerqueira; P J Ell; E J Flint; M Harbinson; A D Kelion; A Al-Mohammad; E M Prvulovich; L J Shaw; A C Tweddel Journal: Eur J Nucl Med Mol Imaging Date: 2004-02 Impact factor: 9.236