Abstract
BACKGROUND: To evaluate functional visual parameters using photocromic and selective blue-violet light filtering spectacle lenses in patients affected by central or peripheral scotoma due to retinal diseases. Sixty patients were enrolled in this study: 30 patients affected by central scotoma, group 1, and 30 affected by peripheral scotoma, group 2. Black on White Best Corrected Visual Acuity (BW-BCVA), White on Black Best Corrected Visual Acuity (WB-BCVA), Mars Contrast Sensitivity (CS) and a Glare Test (GT) were performed to all patients. Test results with blue-violet filter, a short-pass yellow filter and with no filters were compared.Entities:
Keywords: AMD; Blue light; Contrast sensitivity; Glare; Led light; Retinitis pigmentosa
Mesh:
Year: 2017 PMID: 28830379 PMCID: PMC5568170 DOI: 10.1186/s12886-017-0545-9
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Demographic information: for each of the two groups (central or peripheral scotoma) the table reports the male to female ratio in the second column, the mean age in the third column and the distribution of the diseases causing the scotoma within each group
| Demographics Scotoma | M:F | Age (Mean ± SD) | Disease | |
|---|---|---|---|---|
| Central ( | 12:18 | 64 ± 21 |
| 19 |
| Peripheral ( | 13:17 | 49 ± 13 |
| 29 |
Reports all test results before (column 3) and after (column 4) the application of filters
| Test results, Mean (SD) | Without filters | With filters | Mean Subject Increase |
| |
|---|---|---|---|---|---|
| Scotoma | |||||
| Central | BCVA (Black on White) | 0.30 (0.20) | 0.36 (0.21) | 0.057 (0.03) | <0.0001 |
| BCVA (White on Black) | 0.31 (0.19) | 0.38 (0.23) | 0.074 (0.045) | <0.0001 | |
| Glare Test | 20.93 (5.42) | 22.82 (4.93) | 4.52 (1.70) | <0.0001 | |
| Contrast Sensitivity | 26.7 (7.9) | 30.06 (7.8) | 3.37 (1.8) | 0.0005 | |
| Peripheral | BCVA (Black on White) | 0.44 (0.22) | 0.51 (0.23) | 0.074 (0.04) | <0.0001 |
| BCVA (White on Black) | 0.46 (0.2) | 0.56 (0.22) | 0.098 (0.064) | <0.0001 | |
| Glare Test | 24.15 (5.5) | 25.97 (4.7) | 3.75 (1.3) | <0.0001 | |
| Contrast Sensitivity | 31.5 (7.6) | 33.72 (7.3) | 2.25 (1.62) | 0.031 | |
Column 5 reports the mean subject increase (expressed as the average of the individual means of the differences in the test results for the two eyes). All results are reported as Mean (SD). The last column reports the significance of each difference obtained from the linear models described in the Method section. Subjects are divided in patients with central scotoma (top white rows) and peripheral scotoma (bottom gray rows)
Reports the Estimated Difference and Standard Errors (SE) obtained by a randomized trial on NN patients
| Test | Estimated Difference | SE |
| |
|---|---|---|---|---|
| Comparison | ||||
| BCVA (Black on White) | Blue-violet – Yellow | 0.071 | 0.006 | <.0001 |
| Blue-violet – No Filter | 0.078 | 0.005 | <.0001 | |
| Yellow – No Filter | 0.007 | 0.006 | 0.4197 | |
| BCVA (White on Black) | Blue-violet – Yellow | 0.083 | 0.009 | <.0001 |
| Blue-violet – No Filter | 0.088 | 0.008 | <.0001 | |
| Yellow – No Filter | 0.004 | 0.009 | 0.8778 | |
| Glare Test | Blue-violet – Yellow | 0.186 | 0.041 | <.0001 |
| Blue-violet – No Filter | 0.204 | 0.041 | <.0001 | |
| Yellow – No Filter | 0.018 | 0.043 | 0.9123 | |
| Contrast Sensitivity | Blue-violet – Yellow | 0.089 | 0.036 | 0.0363 |
| Blue-violet – No Filter | 0.103 | 0.035 | 0.0094 | |
| Yellow – No Filter | 0.014 | 0.037 | 0.9218 |
Each row block refers to a different test and each row within a block reports all possible differences in the test results between the Blue-violet filter, the Yellow filter and no filter correction. All p-values have been calculated with mixed linear models and corrected with the Tukey-Kramer method