Literature DB >> 28829721

Assessment of indoor levels of volatile organic compounds and carbon dioxide in schools in Kuwait.

Layla Al-Awadi1.   

Abstract

Indoor air quality (IAQ) in schools is a matter of concern because children are most vulnerable and sensitive to pollutant exposure. Conservation of energy at the expense of ventilation in heating, ventilation, and air conditioning (HVAC) systems adversely affects IAQ. Extensive use of new materials in building, fitting, and refurbishing emit various pollutants such that the indoor environment creates its own discomfort and health risks. Various schools in Kuwait were selected to assess their IAQ. Comprehensive measurements of volatile organic compounds (VOCs) consisting of 72 organic compounds consisting of aliphatic (C3-C6), aromatic (C6-C9), halogenated (C1-C7), and oxygenated (C2-C9) functional groups in indoor air were made for the first time in schools in Kuwait. The concentrations of indoor air pollutants revealed hot spots (science preparation rooms, science laboratories, arts and crafts classes/paint rooms, and woodworking shops/decoration rooms where local sources contributed to the buildup of pollutants in each school. The most abundant VOC pollutant was chlorodifluoromethane (R22; ClF2CH), which leaked from air conditioning (AC) systems due to improper operation and maintenance. The other copious VOCs were alcohols and acetone at different locations due to improper handling of the chemicals and their excessive uses as solvents. Indoor carbon dioxide (CO2) levels were measured, and these levels reflected the performance of HVAC systems; a specific rate or lack of ventilation affected the IAQ. Recommendations are proposed to mitigate the buildup of indoor air pollutants at school sites. IMPLICATIONS: Indoor air quality in elementary schools has been a subject of extreme importance due to susceptibility and sensibility of children to air pollutants. The schools were selected based on their surrounding environment especially downwind direction from the highly industrialized zone in Kuwait. Extensive sampling from different sites in four schools for comprehensive VOCs and CO2 were completed for an extended period of over a year. Different hot spots were identified where leaked refrigerant and inadequate handling of laboratory solvents contributed to the high VOCs in the respective locations. CO2 levels reflected HVAC performance and poor ventilation. A list of recommendations has been proposed to eradicate these high levels of air pollution.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28829721     DOI: 10.1080/10962247.2017.1365781

Source DB:  PubMed          Journal:  J Air Waste Manag Assoc        ISSN: 1096-2247            Impact factor:   2.235


  2 in total

1.  Building and indoor environmental quality assessment of Nigerian primary schools: A pilot study.

Authors:  Oluyemi Toyinbo; Wanda Phipatanakul; Richard Shaughnessy; Ulla Haverinen-Shaughnessy
Journal:  Indoor Air       Date:  2019-03-20       Impact factor: 5.770

Review 2.  Indoor air pollution and exposure assessment of the gulf cooperation council countries: A critical review.

Authors:  Patrick Amoatey; Hamid Omidvarborna; Mahad Said Baawain; Abdullah Al-Mamun
Journal:  Environ Int       Date:  2018-10-01       Impact factor: 9.621

  2 in total