Literature DB >> 28829301

Stimulation Efficiency With Decaying Exponential Waveforms in a Wirelessly Powered Switched-Capacitor Discharge Stimulation System.

Hyung-Min Lee, Bryan Howell, Warren M Grill, Maysam Ghovanloo.   

Abstract

The purpose of this study was to test the feasibility of using a switched-capacitor discharge stimulation (SCDS) system for electrical stimulation, and, subsequently, determine the overall energy saved compared to a conventional stimulator. We have constructed a computational model by pairing an image-based volume conductor model of the cat head with cable models of corticospinal tract (CST) axons and quantified the theoretical stimulation efficiency of rectangular and decaying exponential waveforms, produced by conventional and SCDS systems, respectively. Subsequently, the model predictions were tested in vivo by activating axons in the posterior internal capsule and recording evoked electromyography (EMG) in the contralateral upper arm muscles. Compared to rectangular waveforms, decaying exponential waveforms with time constants >500 μs were predicted to require 2%-4% less stimulus energy to activate directly models of CST axons and 0.4%-2% less stimulus energy to evoke EMG activity in vivo. Using the calculated wireless input energy of the stimulation system and the measured stimulus energies required to evoke EMG activity, we predict that an SCDS implantable pulse generator (IPG) will require 40% less input energy than a conventional IPG to activate target neural elements. A wireless SCDS IPG that is more energy efficient than a conventional IPG will reduce the size of an implant, require that less wireless energy be transmitted through the skin, and extend the lifetime of the battery in the external power transmitter.

Entities:  

Mesh:

Year:  2017        PMID: 28829301      PMCID: PMC5931398          DOI: 10.1109/TBME.2017.2741107

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  43 in total

Review 1.  Treatment of motor and non-motor features of Parkinson's disease with deep brain stimulation.

Authors:  Alfonso Fasano; Antonio Daniele; Alberto Albanese
Journal:  Lancet Neurol       Date:  2012-05       Impact factor: 44.182

Review 2.  Energy sources and their development for application in medical devices.

Authors:  Mahdi Rasouli; Louis Soo Jay Phee
Journal:  Expert Rev Med Devices       Date:  2010-09       Impact factor: 3.166

3.  Non-rectangular waveforms for neural stimulation with practical electrodes.

Authors:  Mesut Sahin; Yanmei Tie
Journal:  J Neural Eng       Date:  2007-05-02       Impact factor: 5.379

4.  A 13.56 MHz CMOS Active Rectifier With Switched-Offset and Compensated Biasing for Biomedical Wireless Power Transfer Systems.

Authors: 
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2013-07-02       Impact factor: 3.833

5.  Design and optimization of printed spiral coils for efficient transcutaneous inductive power transmission.

Authors:  M Ghovanloo
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2007-09       Impact factor: 3.833

Review 6.  Descending pathways in motor control.

Authors:  Roger N Lemon
Journal:  Annu Rev Neurosci       Date:  2008       Impact factor: 12.449

7.  Efficiency analysis of waveform shape for electrical excitation of nerve fibers.

Authors:  Amorn Wongsarnpigoon; John P Woock; Warren M Grill
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2010-04-12       Impact factor: 3.802

8.  A new rechargeable device for deep brain stimulation: a prospective patient satisfaction survey.

Authors:  Lars Timmermann; Michael Schüpbach; Frank Hertel; Elisabeth Wolf; Roberto Eleopra; Angelo Franzini; Domenico Servello; Inger-Marie Skogseid; Jordi Rumia; Antonio Salvador Aliaga; Michael T Barbe; K Amande M Pauls; Jean-Pierre Lin; Elena Moro; Andrew Lloyd; Mohammad Maarouf
Journal:  Eur Neurol       Date:  2013-01-10       Impact factor: 1.710

9.  Characterization of tissue morphology, angiogenesis, and temperature in the adaptive response of muscle tissue to chronic heating.

Authors:  T M Seese; H Harasaki; G M Saidel; C R Davies
Journal:  Lab Invest       Date:  1998-12       Impact factor: 5.662

Review 10.  Deep brain stimulation and tremor.

Authors:  Kelly E Lyons; Rajesh Pahwa
Journal:  Neurotherapeutics       Date:  2008-04       Impact factor: 7.620

View more
  1 in total

1.  Full-duplex enabled wireless power transfer system via textile for miniaturized IMD.

Authors:  Jaeho Lee; Beomjun Bae; Beomjin Kim; Byunghun Lee
Journal:  Biomed Eng Lett       Date:  2022-07-17
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.