| Literature DB >> 28828013 |
Farzin Heravi1, Maryam Omidkhoda2, Niloufar Koohestanian3, Tabassom Hooshmand4, Hossein Bagheri5, Negin Ghaffari6.
Abstract
OBJECTIVES: The aim of this study was to evaluate and compare the retentive strength of orthodontic bands cemented with amorphous calcium phosphate (ACP)-containing and conventional glass ionomer cements (GICs).Entities:
Keywords: Amorphous Calcium Phosphate; Glass Ionomer Cements; Retention
Year: 2017 PMID: 28828013 PMCID: PMC5557992
Source DB: PubMed Journal: J Dent (Tehran) ISSN: 1735-2150
Fig. 1:Mounted tooth clamped to a customized holding device fixed to the lower load cell of the universal testing machine
Fig. 2:Customized band removal device used to simulate clinical load for measurement of retentive strength
Descriptive statistics (in megapascals) of the retentive strength (RS) of experimental groups (n=30)
| Thermocycling | 1.2961 | 0.35308 | 0.016 | |
| No thermocycling | 1.5140 | 0.32736 | ||
| Thermocycling | 1.3691 | 0.25306 | 0.001 | |
| No thermocycling | 1.1695 | 0.18393 |
GI: Glass ionomer; ACP: Amorphous calcium phosphate
Level of significance <0.05
Fig. 3:Interaction effect of type of glass ionomer and thermocycling (T) based on two-way ANOVA
Independent samples t-test for evaluation of effect of thermocycling on retentive strength
| Group 1 | 1.5140 | 0.32736 | 0.05977 | 1.3917 | 1.6362 | 0.92 | 2.40 |
| Group 2 | 1.1695 | 0.18393 | 0.03358 | 1.1008 | 1.2382 | 0.70 | 1.57 |
| Group 3 | 1.2961 | 0.35308 | 0.06446 | 1.1642 | 1.4279 | 0.52 | 2.09 |
| Group 4 | 1.3691 | 0.25306 | 0.04620 | 1.2746 | 1.4636 | 0.97 | 1.94 |
Independent samples test for comparison of retentive strength of groups
| GI | 1.2961 | 0.35308 | 0.36 | |
| ACP | 1.3691 | 0.25306 | ||
| GI | 1.5140 | 0.32736 | 0.00 | |
| ACP | 1.1695 | 0.18393 |
Level of significance <0.05
GI: Glass ionomer; ACP: Amorphous calcium phosphate