Abstract

BACKGROUND: Previous studies have proposed various ways to assess scapular dyskinesis. In clinic, assessment tools designed to measure the posterior displacement of the inferior angle of the scapula with reference to the posterior thoracic cage are needed.
OBJECTIVES: A novel scapulometer was developed to measure scapular medial border and inferior angle prominence.
METHODS: A novel scapulometer was designed to measure the distance from the root of the spine (ROS) and the inferior angle (INF) of the scapula to the thorax wall in 29 participants with scapular dyskinesis bilaterally. Two raters measured the ROS and INF distance of the scapula 3 times bilaterally. Intraclass correlation coefficients (ICC) and standard error of measurement (SEM) were calculated to determine the inter-rater and intra-rater reliability. Validity was based on correlations (convergent: ROS and internal/external rotation, and INF and tilt; divergent: ROS/INF and upward rotation of the scapula) using a FASTRAK Polhemus 3-D motion tracking system assessing scapular tilt, internal/external rotation, and upward/downward rotation.
RESULTS: The average ROS and INF displacements were 13.7 ± 5.0 mm and 12.5 ± 6.3 mm, respectively. The results showed excellent intra-rater and inter-rater reliability, with ICC = 0.88-0.99 and 0.95-0.99 (SEM = 0.7-0.8 mm), respectively. Correlations were 0.35/0.19 (convergent validity) and 0.07/0.09 (divergent validity).
CONCLUSIONS: The novel scapulometer has excellent reliability and fair validity to quantify medial border and inferior angle prominence of the scapula. Further research utilizing this instrument is recommended.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Dyskinesis; Reliability; Scapulometer; Validity

Mesh:

Year:  2017        PMID: 28827031     DOI: 10.1016/j.msksp.2017.08.004

Source DB:  PubMed          Journal:  Musculoskelet Sci Pract        ISSN: 2468-7812            Impact factor:   2.520


  4 in total

1.  Reliability of assessment methods for scapular dyskinesis in asymptomatic subjects: A systematic review.

Authors:  Eleftherios Paraskevopoulos; Maria Papandreou; John Gliatis
Journal:  Acta Orthop Traumatol Turc       Date:  2020-09       Impact factor: 1.511

2.  Clinical Factors Related to Improved Scapular Control After a Scapular Conscious Control Program in Symptomatic Overhead Athletes: Secondary Analysis of a Randomized Controlled Trial.

Authors:  Tsun-Shun Huang; Wan-Yu Du; Jiu-Jenq Lin
Journal:  Orthop J Sports Med       Date:  2020-11-30

3.  Scapular Dyskinesis: From Basic Science to Ultimate Treatment.

Authors:  Umile Giuseppe Longo; Laura Risi Ambrogioni; Alessandra Berton; Vincenzo Candela; Carlo Massaroni; Arianna Carnevale; Giovanna Stelitano; Emiliano Schena; Ara Nazarian; Joseph DeAngelis; Vincenzo Denaro
Journal:  Int J Environ Res Public Health       Date:  2020-04-24       Impact factor: 3.390

4.  Hand Measurement System Based on Haptic and Vision Devices towards Post-Stroke Patients.

Authors:  Katarzyna Koter; Martyna Samowicz; Justyna Redlicka; Igor Zubrycki
Journal:  Sensors (Basel)       Date:  2022-03-07       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.