Literature DB >> 28826893

Effect of Bleeding Risk on Type of Stent Used in Patients Presenting With Acute Coronary Syndrome.

M Chadi Alraies1, Sang Yeub Lee1, Michael J Lipinski1, Kyle Buchanan1, Arie Steinvil1, Toby Rogers1, Edward Koifman1, Jiaxiang Gai1, Rebecca Torguson1, Itsik Ben-Dor1, Lowell F Satler1, Augusto D Pichard1, Ron Waksman2.   

Abstract

Patients at high bleeding risk (HBR) are at increased risk of bleeding following percutaneous coronary intervention (PCI) with drug-eluting stents (DES) due to the need for longer dual antiplatelet duration. We sought to evaluate the likelihood of receiving DES during PCI in HBR populations and to characterize DES utilization trends over time. Consecutive patients who underwent PCI from April 2003 to September 2015 were identified. HBR is defined as patients fulfilling 1 or more of the HBR criteria: age ≥75 years, anticoagulation use at discharge, history of stroke, cancer in previous 3 years, glucocorticoid use, hemoglobin (Hgb) <11 g/dl, platelet count <100,000/mm3, or creatinine clearance (CCr) <40 ml/min. Multivariate analysis was performed to identify which variables predicted DES selection. There were 10,594 patients (41.6%) who the met HBR definition. When adjusting for known risk factors, HBR patients were less likely to receive a DES compared with non-HBR patients (odds ratio [OR] 0.58, 95% confidence interval [CI] 0.54 to 0.62, p <0.001). A preprocedural Hgb <11 g/dl had the greatest association with choosing DES during PCI (OR 0.51, 95% CI 0.45 to 0.57, p <0.001). Within the HBR patients, having 3 or more HBR criteria versus <3 HBR criteria had lower likelihood of receiving a DES (OR 0.50, 95% CI 0.44 to 0.57, p <0.001). In conclusion, presence of HBR has a significant impact upon the decision to use DES.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28826893     DOI: 10.1016/j.amjcard.2017.07.013

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  1 in total

1.  High Bleeding Risk Patients Treated with Very Thin-Strut Biodegradable Polymer or Thin-Strut Durable Polymer Drug-Eluting Stents in the BIO-RESORT Trial.

Authors:  Paolo Zocca; Marlies M Kok; Liefke C van der Heijden; Peter W Danse; Carl E Schotborgh; Martijn Scholte; Marc Hartmann; Gerard C M Linssen; Carine J M Doggen; Clemens von Birgelen
Journal:  Cardiovasc Drugs Ther       Date:  2018-12       Impact factor: 3.727

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.