Literature DB >> 28819725

Simultaneous Improvement of Resolving Power and Signal-to-Noise Ratio Using a Modified Hadamard Transform-Inverse Ion Mobility Spectrometry Technique.

Yan Hong1,2, Sheng Liu3, Chaoqun Huang4, Lei Xia1, Chengyin Shen1, Haihe Jiang1, Yannan Chu5.   

Abstract

In order to improve the resolving power (RP) and signal-to-noise ratio (SNR) of ion mobility spectrometry (IMS) simultaneously, a modified Hadamard transform-inverse ion mobility spectrometry (MHT-IIMS) technique was developed. In this novel technique, a series of isolating codes were appended to each element of the pseudo random binary sequence (PRBS), and then the modified modulation sequence was formed and used to control the ion gate of the inverse IMS (IIMS). Experimental results demonstrate that the MHT-IIMS technique can significantly enhance the resolving power and SNR simultaneously by measuring the spectra of reaction ions. Furthermore, the gas sample CCl4 and CHCl3 were measured for evaluating the capability of detecting those samples which have single and multiple product ions. The results show that this novel technique is able to simultaneously improve the resolving power and SNR notablely for the real sample detection without any significant instrumental changes. Graphical Abstract ᅟ.

Entities:  

Keywords:  Hadamard transform inverse ion mobility spectrometry; Isolating code; Resolving power; Signal-to-noise ratio

Year:  2017        PMID: 28819725     DOI: 10.1007/s13361-017-1773-1

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  19 in total

1.  Hadamard transform ion mobility spectrometry.

Authors:  Brian H Clowers; William F Siems; Herbert H Hill; Steven M Massick
Journal:  Anal Chem       Date:  2006-01-01       Impact factor: 6.986

2.  Enhanced ion utilization efficiency using an electrodynamic ion funnel trap as an injection mechanism for ion mobility spectrometry.

Authors:  Brian H Clowers; Yehia M Ibrahim; David C Prior; William F Danielson; Mikhail E Belov; Richard D Smith
Journal:  Anal Chem       Date:  2008-01-01       Impact factor: 6.986

3.  Analysis of explosives using electrospray ionization/ion mobility spectrometry (ESI/IMS).

Authors:  G R Asbury; J Klasmeier; H H Hill
Journal:  Talanta       Date:  2000-01-10       Impact factor: 6.057

4.  Improved ion mobility resolving power with increased buffer gas pressure.

Authors:  Eric J Davis; Kristopher F Grows; William F Siems; Herbert H Hill
Journal:  Anal Chem       Date:  2012-05-23       Impact factor: 6.986

5.  Detection of designer drugs in human hair by ion mobility spectrometry (IMS).

Authors:  T Keller; A Miki; P Regenscheit; R Dirnhofer; A Schneider; H Tsuchihashi
Journal:  Forensic Sci Int       Date:  1998-06-08       Impact factor: 2.395

6.  Hadamard transform capillary electrophoresis.

Authors:  T Kaneta; Y Yamaguchi; T Imasaka
Journal:  Anal Chem       Date:  1999-12-01       Impact factor: 6.986

7.  Desorption electrospray ionization (DESI) with atmospheric pressure ion mobility spectrometry for drug detection.

Authors:  Kristyn M Roscioli; Jessica A Tufariello; Xing Zhang; Shelly X Li; Gilles H Goetz; Guilong Cheng; William F Siems; Herbert H Hill
Journal:  Analyst       Date:  2014-04-07       Impact factor: 4.616

8.  Applications of Hadamard transform to gas chromatography/mass spectrometry and liquid chromatography/mass spectrometry.

Authors:  Cheng-Huang Lin; Takashi Kaneta; Hung-Ming Chen; Wen-Xiong Chen; Hung-Wei Chang; Ju-Tsung Liu
Journal:  Anal Chem       Date:  2008-06-21       Impact factor: 6.986

9.  High-pressure ion mobility spectrometry.

Authors:  Eric J Davis; Prabha Dwivedi; Maggie Tam; William F Siems; Herbert H Hill
Journal:  Anal Chem       Date:  2009-05-01       Impact factor: 6.986

10.  Portable solid phase micro-extraction coupled with ion mobility spectrometry system for on-site analysis of chemical warfare agents and simulants in water samples.

Authors:  Liu Yang; Qiang Han; Shuya Cao; Jie Yang; Junchao Yang; Mingyu Ding
Journal:  Sensors (Basel)       Date:  2014-11-06       Impact factor: 3.576

View more
  1 in total

1.  Miniaturized Photo-Ionization Fourier Deconvolution Ion Mobility Spectrometer for the Detection of Volatile Organic Compounds.

Authors:  Binwang Yang; Jianna Yu; Wen Liu; Guoxing Jing; Wenshan Li; Wenjie Liu
Journal:  Sensors (Basel)       Date:  2022-07-22       Impact factor: 3.847

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.