| Literature DB >> 28819481 |
Negussie Alula Bekele1, Worknehe Agegnehu Abebe1, Jemal Zeberga Shifa2.
Abstract
Percutaneous Central Venous Catheter (CVC) insertion using internal jugular and Subclavian veins routes is common procedure for all intensive care admitted patients and some patients in the ward as demand arises in central and referral hospitals of Botswana. This is a case report of a patient on whom a third attempt of re-inserting a CVC for fluid and total parenteral nutrition (TPN) was made. X-ray showed that left Subclavian inserted catheter was mis-directed to internal jugular vein of the same side creating discomfort to the patient. Ultra sound is recommended for routine investigation to confirm proper Central venous catheter placement as it can reduce failure, minimize complication and reduce cost of treatment.Entities:
Keywords: Central venous catheter; misplacement
Mesh:
Year: 2017 PMID: 28819481 PMCID: PMC5554667 DOI: 10.11604/pamj.2017.27.59.9532
Source DB: PubMed Journal: Pan Afr Med J
Figure 1Patients CXR
Figure 2Patients Neck and Head X-ray