Literature DB >> 28817381

Advanced Radiation DOSimetry phantom (ARDOS): a versatile breathing phantom for 4D radiation therapy and medical imaging.

Natalia Kostiukhina1, Dietmar Georg, Sofia Rollet, Peter Kuess, Andrej Sipaj, Piotr Andrzejewski, Hugo Furtado, Ivo Rausch, Wolfgang Lechner, Elisabeth Steiner, Hunor Kertész, Barbara Knäusl.   

Abstract

A novel breathing phantom was designed for being used in conventional and ion-beam radiotherapy as well as for medical imaging. Accurate dose delivery and patient safety are aimed to be verified for four-dimensional (4D) treatment techniques compensating for breathing-induced tumor motion. The phantom includes anthropomorphic components representing an average human thorax. It consists of real tissue equivalent materials to fulfill the requirements for dosimetric experiments and imaging purposes. The different parts of the torso (lungs, chest wall, and ribs) and the tumor can move independently. Simple regular movements, as well as more advanced patient-specific breathing cycles are feasible while a reproducible setup can be guaranteed. The phantom provides the flexibility to use different types of dosimetric devices and was designed in a way that it is robust, transportable and easy to handle. Tolerance levels and the reliability of the phantom setup were determined in combination with tests on motion accuracy and reproducibility by using infrared optical tracking technology. Different imaging was performed including positron emission tomography imaging, 4D computed tomography as well as real-time in-room imaging. The initial dosimetric benchmarking studies were performed in a photon beam where dose parameters are predictable and the dosimetric procedures well established.

Entities:  

Mesh:

Year:  2017        PMID: 28817381     DOI: 10.1088/1361-6560/aa86ea

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Additively Manufactured Patient-Specific Anthropomorphic Thorax Phantom With Realistic Radiation Attenuation Properties.

Authors:  Sepideh Hatamikia; Gunpreet Oberoi; Ewald Unger; Gernot Kronreif; Joachim Kettenbach; Martin Buschmann; Michael Figl; Barbara Knäusl; Francesco Moscato; Wolfgang Birkfellner
Journal:  Front Bioeng Biotechnol       Date:  2020-05-08

2.  The Influence of Motion on the Delivery Accuracy When Comparing Actively Scanned Carbon Ions versus Protons at a Synchrotron-Based Radiotherapy Facility.

Authors:  Franciska Lebbink; Markus Stock; Dietmar Georg; Barbara Knäusl
Journal:  Cancers (Basel)       Date:  2022-03-31       Impact factor: 6.639

3.  A novel bone suppression algorithm in intensity-based 2D/3D image registration for real-time tumor motion monitoring: Development and phantom-based validation.

Authors:  Ingo Gulyas; Petra Trnkova; Barbara Knäusl; Joachim Widder; Dietmar Georg; Andreas Renner
Journal:  Med Phys       Date:  2022-06-06       Impact factor: 4.506

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.