Plasma of Argon Cleaning Treatment on Implant Abutments in Periodontally Healthy Patients: Six Years Postloading Results of a Randomized Controlled Trial.

Luigi Canullo, Marco Tallarico, Miguel Penarrocha, Giuseppe Corrente, Joseph Fiorellini, David Penarrocha.   

Abstract

The aim of this randomized, match-paired, triple-blinded, controlled clinical trial was to assess the 6-year radiographic changes around customized platform-switched abutments placed according to the one abutment-one time concept, with and without plasma of argon cleaning treatment. A total of 20 periodontally healthy patients received one maxillary implant between the premolars. Immediately before stage 2 surgery and abutment connection, patients were randomly assigned to the control (cleaning protocol by steam) or test group (plasma of argon treatment). Periapical standardized digital radiographs were taken at the time of crown connection (T₀) and at 12 (T₁), 24 (T₂), 48 (T₄), 60 (T₅), and 72 months (T₆) after the final restoration delivery. Primary outcome measures were the success rates of the implants and prostheses and the occurrence of any technical and biologic complications during the follow-up period. Secondary outcome measures were peri-implant marginal bone level changes, bleeding on probing, and plaque score. Two patients (one in test and one in control group) dropped out at the last follow-up. Neither implant nor prosthetic complications were detected in the analyzed patients of both groups during the 6-year follow-up examinations. Radiographic analysis revealed a statistically significant higher mean bone loss in the control group than in the test group at T₂ (0.4 ± 0.28 mm; P = .018), T₄ (0.52 ± 0.63 mm; P = .037), T₅ (0.61 ± 0.70 mm; P = .038), and T₆ (0.71 ± 0.66 mm; P = .011), but not at T₁ (P = .131). From baseline to the 6-year follow-up, intragroup comparisons showed an absence of statistically significant difference in the test group (P = .08). Conversely, significant differences were found in the control group (P = .01). All implants demonstrated successful periodontal parameters, with no significant differences between groups. The results of this present study indicate that contaminant and bacterial removal from abutments in two-stage implants using plasma of argon could represent a positive strategy to minimize peri-implant bone resorption and longitudinally stabilize esthetic outcomes.

Entities:  

Mesh:

Year:  2017        PMID: 28817132     DOI: 10.11607/prd.3079

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  2 in total

1.  Effect Morphology and Surface Treatment of the Abutments of Dental Implants on the Dimension and Health of Peri-Implant Biological Space.

Authors:  Ibrahim Dib-Zaitum; Yasmina Guadilla-González; Javier Flores-Fraile; Juan Dib-Zakkour; Lorena Benito-Garzón; Javier Montero
Journal:  Materials (Basel)       Date:  2022-06-22       Impact factor: 3.748

2.  The role of argon in dentistry.

Authors:  Thorakkal Shamim
Journal:  Med Gas Res       Date:  2018-09-25