Effect of Missing Inter-Beat Interval Data on Heart Rate Variability Analysis Using Wrist-Worn Wearables.

Hyun Jae Baek1, JaeWook Shin2.   

Abstract

Most of the wrist-worn devices on the market provide a continuous heart rate measurement function using photoplethysmography, but have not yet provided a function to measure the continuous heart rate variability (HRV) using beat-to-beat pulse interval. The reason for such is the difficulty of measuring a continuous pulse interval during movement using a wearable device because of the nature of photoplethysmography, which is susceptible to motion noise. This study investigated the effect of missing heart beat interval data on the HRV analysis in cases where pulse interval cannot be measured because of movement noise. First, we performed simulations by randomly removing data from the RR interval of the electrocardiogram measured from 39 subjects and observed the changes of the relative and normalized errors for the HRV parameters according to the total length of the missing heart beat interval data. Second, we measured the pulse interval from 20 subjects using a wrist-worn device for 24 h and observed the error value for the missing pulse interval data caused by the movement during actual daily life. The experimental results showed that mean NN and RMSSD were the most robust for the missing heart beat interval data among all the parameters in the time and frequency domains. Most of the pulse interval data could not be obtained during daily life. In other words, the sample number was too small for spectral analysis because of the long missing duration. Therefore, the frequency domain parameters often could not be calculated, except for the sleep state with little motion. The errors of the HRV parameters were proportional to the missing data duration in the presence of missing heart beat interval data. Based on the results of this study, the maximum missing duration for acceptable errors for each parameter is recommended for use when the HRV analysis is performed on a wrist-worn device.

Keywords:  Heart rate variability (HRV); Missing data; Photoplethysmography (PPG); Wrist-worn device

Mesh:

Year:  2017        PMID: 28812280     DOI: 10.1007/s10916-017-0796-2

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  15 in total

Review 1.  Photoplethysmography and its application in clinical physiological measurement.

Authors:  John Allen
Journal:  Physiol Meas       Date:  2007-02-20       Impact factor: 2.833

2.  Nonintrusive biological signal monitoring in a car to evaluate a driver's stress and health state.

Authors:  Hyun Jae Baek; Haet Bit Lee; Jung Soo Kim; Jong Min Choi; Ko Keun Kim; Kwang Suk Park
Journal:  Telemed J E Health       Date:  2009-03       Impact factor: 3.536

Review 3.  The relationship between mental and physical health: insights from the study of heart rate variability.

Authors:  Andrew H Kemp; Daniel S Quintana
Journal:  Int J Psychophysiol       Date:  2013-06-22       Impact factor: 2.997

4.  Heart rate variability. Standards of measurement, physiological interpretation, and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology.

Authors: 
Journal:  Eur Heart J       Date:  1996-03       Impact factor: 29.983

5.  Comparison of foot finding methods for deriving instantaneous pulse rates from photoplethysmographic signals.

Authors:  Mathilde C Hemon; Justin P Phillips
Journal:  J Clin Monit Comput       Date:  2015-04-24       Impact factor: 2.502

6.  Reliability of ultra-short-term analysis as a surrogate of standard 5-min analysis of heart rate variability.

Authors:  Hyun Jae Baek; Chul-Ho Cho; Jaegeol Cho; Jong-Min Woo
Journal:  Telemed J E Health       Date:  2015-03-25       Impact factor: 3.536

Review 7.  A review of wearable technology in medicine.

Authors:  Mohammed H Iqbal; Abdullatif Aydin; Oliver Brunckhorst; Prokar Dasgupta; Kamran Ahmed
Journal:  J R Soc Med       Date:  2016-10       Impact factor: 5.344

8.  On the validity of using the Polar RS800 heart rate monitor for heart rate variability research.

Authors:  Daniel S Quintana; James A J Heathers; Andrew H Kemp
Journal:  Eur J Appl Physiol       Date:  2012-07-13       Impact factor: 3.078

Review 9.  Health at hand: A systematic review of smart watch uses for health and wellness.

Authors:  Blaine Reeder; Alexandria David
Journal:  J Biomed Inform       Date:  2016-09-06       Impact factor: 6.317

Review 10.  Heart Rate Variability: New Perspectives on Physiological Mechanisms, Assessment of Self-regulatory Capacity, and Health risk.

Authors:  Rollin McCraty; Fred Shaffer
Journal:  Glob Adv Health Med       Date:  2015-01
View more
  9 in total

Review 1.  Heart Rate Variability: An Old Metric with New Meaning in the Era of using mHealth Technologies for Health and Exercise Training Guidance. Part One: Physiology and Methods.

Authors:  Nikhil Singh; Kegan James Moneghetti; Jeffrey Wilcox Christle; David Hadley; Daniel Plews; Victor Froelicher
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

2.  Intra-Individual Variation of HRV during Orthostatic Challenge in Elite Male Field Hockey Players.

Authors:  Jason D Vescovi
Journal:  J Med Syst       Date:  2019-10-27       Impact factor: 4.460

3.  Associations Between Heart Rate Variability Measured With a Wrist-Worn Sensor and Older Adults' Physical Function: Observational Study.

Authors:  Sarah Anne Graham; Dilip V Jeste; Ellen E Lee; Tsung-Chin Wu; Xin Tu; Ho-Cheol Kim; Colin A Depp
Journal:  JMIR Mhealth Uhealth       Date:  2019-10-23       Impact factor: 4.773

4.  Assessing the Accuracy of Popular Commercial Technologies That Measure Resting Heart Rate and Heart Rate Variability.

Authors:  Jason D Stone; Hana K Ulman; Kaylee Tran; Andrew G Thompson; Manuel D Halter; Jad H Ramadan; Mark Stephenson; Victor S Finomore; Scott M Galster; Ali R Rezai; Joshua A Hagen
Journal:  Front Sports Act Living       Date:  2021-03-01

Review 5.  Modulation Spectral Signal Representation for Quality Measurement and Enhancement of Wearable Device Data: A Technical Note.

Authors:  Abhishek Tiwari; Raymundo Cassani; Shruti Kshirsagar; Diana P Tobon; Yi Zhu; Tiago H Falk
Journal:  Sensors (Basel)       Date:  2022-06-17       Impact factor: 3.847

6.  Wrist Photoplethysmography Signal Quality Assessment for Reliable Heart Rate Estimate and Morphological Analysis.

Authors:  Serena Moscato; Stella Lo Giudice; Giulia Massaro; Lorenzo Chiari
Journal:  Sensors (Basel)       Date:  2022-08-04       Impact factor: 3.847

7.  Effects of Missing Data on Heart Rate Variability Metrics.

Authors:  Diego Cajal; David Hernando; Jesús Lázaro; Pablo Laguna; Eduardo Gil; Raquel Bailón
Journal:  Sensors (Basel)       Date:  2022-08-02       Impact factor: 3.847

8.  Snoozing: an examination of a common method of waking.

Authors:  Stephen M Mattingly; Gonzalo Martinez; Jessica Young; Meghan K Cain; Aaron Striegel
Journal:  Sleep       Date:  2022-10-10       Impact factor: 6.313

9.  Validation of a Low-Cost Electrocardiography (ECG) System for Psychophysiological Research.

Authors:  Ruth Erna Wagner; Hugo Plácido da Silva; Klaus Gramann
Journal:  Sensors (Basel)       Date:  2021-06-30       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.