Literature DB >> 28812138

[Telemetric follow-up of implantable electronic cardiac devices : Optimisation of care in clinical practice].

Ralph Bosch1, Ingrid Mutscher2.   

Abstract

Remote follow-up of patients with implantable electronic cardiac devices (IECD) is a scientifically well-evaluated and technically mature method. Advantages over conventional follow-up include rapid detection of clinically relevant events (i. e. arrhythmias) and of technical problems. Additionally, telemetric follow-up of IECDs has a high degree of acceptance among both patients as well as health care professionals and carries the potential to reduce health care costs. The implementation of a remote follow-up programme is associated with organisational, infrastructural and legal aspects, which are reviewed.

Entities:  

Keywords:  Arrhythmias; Cardiac pacemaker; Implantable cardioverter-defibrillator; Telemedicine; Telemetry

Mesh:

Year:  2017        PMID: 28812138     DOI: 10.1007/s00399-017-0522-2

Source DB:  PubMed          Journal:  Herzschrittmacherther Elektrophysiol        ISSN: 0938-7412


  4 in total

1.  HRS Expert Consensus Statement on remote interrogation and monitoring for cardiovascular implantable electronic devices.

Authors:  David Slotwiner; Niraj Varma; Joseph G Akar; George Annas; Marianne Beardsall; Richard I Fogel; Nestor O Galizio; Taya V Glotzer; Robin A Leahy; Charles J Love; Rhondalyn C McLean; Suneet Mittal; Loredana Morichelli; Kristen K Patton; Merritt H Raitt; Renato Pietro Ricci; John Rickard; Mark H Schoenfeld; Gerald A Serwer; Julie Shea; Paul Varosy; Atul Verma; Cheuk-Man Yu
Journal:  Heart Rhythm       Date:  2015-05-14       Impact factor: 6.343

2.  Implant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trial.

Authors:  Gerhard Hindricks; Milos Taborsky; Michael Glikson; Ullus Heinrich; Burghard Schumacher; Amos Katz; Johannes Brachmann; Thorsten Lewalter; Andreas Goette; Michael Block; Josef Kautzner; Stefan Sack; Daniela Husser; Christopher Piorkowski; Peter Søgaard
Journal:  Lancet       Date:  2014-08-16       Impact factor: 79.321

Review 3.  Remote Monitoring of Implantable Cardioverter-Defibrillators: A Systematic Review and Meta-Analysis of Clinical Outcomes.

Authors:  Nirmalatiban Parthiban; Adrian Esterman; Rajiv Mahajan; Darragh J Twomey; Rajeev K Pathak; Dennis H Lau; Kurt C Roberts-Thomson; Glenn D Young; Prashanthan Sanders; Anand N Ganesan
Journal:  J Am Coll Cardiol       Date:  2015-05-13       Impact factor: 24.094

Review 4.  Effect of telemonitoring of cardiac implantable electronic devices on healthcare utilization: a meta-analysis of randomized controlled trials in patients with heart failure.

Authors:  Catherine Klersy; Giuseppe Boriani; Annalisa De Silvestri; Georges H Mairesse; Frieder Braunschweig; Valeria Scotti; Anna Balduini; Martin R Cowie; Francisco Leyva
Journal:  Eur J Heart Fail       Date:  2016-01-27       Impact factor: 15.534

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.