Literature DB >> 28804946

Coefficient of Variance as Quality Criterion for Evaluation of Advanced Hepatic Fibrosis Using 2D Shear-Wave Elastography.

Sanghyeok Lim1, Seung Hyun Kim1,2, Yongsoo Kim1, Young Seo Cho1, Tae Yeob Kim3, Woo Kyoung Jeong4, Joo Hyun Sohn5.   

Abstract

OBJECTIVES: To compare the diagnostic performance for advanced hepatic fibrosis measured by 2D shear-wave elastography (SWE), using either the coefficient of variance (CV) or the interquartile range divided by the median value (IQR/M) as quality criteria.
METHODS: In this retrospective study, from January 2011 to December 2013, 96 patients, who underwent both liver stiffness measurement by 2D SWE and liver biopsy for hepatic fibrosis grading, were enrolled. The diagnostic performances of the CV and the IQR/M were analyzed using receiver operating characteristic curves with areas under the curves (AUCs) and were compared by Fisher's Z test, based on matching the cutoff points in an interactive dot diagram. All P values less than 0.05 were considered significant.
RESULTS: When using the cutoff value IQR/M of 0.21, the matched cutoff point of CV was 20%. When a cutoff value of CV of 20% was used, the diagnostic performance for advanced hepatic fibrosis ( ≥ F3 grade) with CV of less than 20% was better than that in the group with CV greater than or equal to 20% (AUC 0.967 versus 0.786, z statistic = 2.23, P = .025), whereas when the matched cutoff value IQR/M of 0.21 showed no difference (AUC 0.918 versus 0.927, z statistic = -0.178, P = .859).
CONCLUSIONS: The validity of liver stiffness measurements made by 2D SWE for assessing advanced hepatic fibrosis may be judged using CVs, and when the CV is less than 20% it can be considered "more reliable" than using IQR/M of less than 0.21.
© 2017 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  elastography; hepatic fibrosis; hepatobiliary; liver cirrhosis; sonoelastography

Mesh:

Year:  2017        PMID: 28804946     DOI: 10.1002/jum.14341

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  1 in total

1.  Test-retest repeatability of ultrasonographic shear wave elastography in a rat liver fibrosis model: toward a quantitative biomarker for preclinical trials.

Authors:  Youngbin Shin; Jimi Huh; Su Jung Ham; Young Chul Cho; Yoonseok Choi; Dong-Cheol Woo; Jeongjin Lee; Kyung Won Kim
Journal:  Ultrasonography       Date:  2020-04-23
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.