Phase separation of in situ forming poly (lactide-co-glycolide acid) implants investigated using a hydrogel-based subcutaneous tissue surrogate and UV-vis imaging.

Yu Sun1, Henrik Jensen2, Nickolaj J Petersen3, Susan W Larsen4, Jesper Østergaard5.   

Abstract

Phase separation of in situ forming poly (lactide-co-glycolide acid) (PLGA) implants with agarose hydrogels as the provider of nonsolvent (water) mimicking subcutaneous tissue was investigated using a novel UV-vis imaging-based analytical platform. In situ forming implants of PLGA-1-methyl-2-pyrrolidinone and PLGA-triacetin representing fast and slow phase separating systems, respectively, were evaluated using this platform. Upon contact with the agarose hydrogel, the phase separation of the systems was followed by the study of changes in light transmission and absorbance as a function of time and position. For the PLGA-1-methyl-2-pyrrolidinone system, the rate of spatial phase separation was determined and found to decrease with increasing the PLGA concentration from 20% to 40% (w/w). Hydrogels with different agarose concentrations (1% and 10% (w/v)) were prepared for providing the nonsolvent, water, to the in situ forming PLGA implants simulating the injection site environment. The resulting implant morphology depended on the stiffness of hydrogel matrix, indicating that the matrix in which implants are formed is of importance. Overall, the work showed that the UV-vis imaging-based platform with an agarose hydrogel mimicking the subcutaneous tissue holds potential in providing bio-relevant and mechanistic information on the phase separation processes of in situ forming implants.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Hydrogel; In situ forming implants; Phase separation; Poly (lactide-co-glycolide acid) (PLGA); UV–vis imaging

Mesh:

Substances:

Year:  2017        PMID: 28803207     DOI: 10.1016/j.jpba.2017.07.056

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

1.  How bulk fluid renewal can affect in vitro drug release from PLGA implants: Importance of the experimental set-up.

Authors:  C Bassand; L Benabed; J Freitag; J Verin; F Siepmann; J Siepmann
Journal:  Int J Pharm X       Date:  2022-09-19

2.  Effect of Polymer Permeability and Solvent Removal Rate on In Situ Forming Implants: Drug Burst Release and Microstructure.

Authors:  Xiaowei Zhang; Liqun Yang; Chong Zhang; Danhua Liu; Shu Meng; Wei Zhang; Shengnan Meng
Journal:  Pharmaceutics       Date:  2019-10-10       Impact factor: 6.321

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.