Literature DB >> 28801046

CON4EI: Short Time Exposure (STE) test method for hazard identification and labelling of eye irritating chemicals.

E Adriaens1, J A Willoughby2, B R Meyer2, L C Blakeman2, N Alépée3, P Fochtman4, R Guest5, H Kandarova6, S Verstraelen7, A R Van Rompay7.   

Abstract

Assessment of ocular irritancy is an international regulatory requirement in the safety evaluation of industrial and consumer products. Although many in vitro ocular irritation assays exist, alone they are incapable of fully categorizing chemicals. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium was developed to assess the reliability of eight in vitro test methods and establish an optimal tiered-testing strategy. One assay selected was the Short Time Exposure (STE) assay. This assay measures the viability of SIRC rabbit corneal cells after 5min exposure to 5% and 0.05% solutions of test material, and is capable of categorizing of Category 1 and No Category chemicals. The accuracy of the STE test method to identify Cat 1 chemicals was 61.3% with 23.7% sensitivity and 95.2% specificity. If non-soluble chemicals and unqualified results were excluded, the performance to identify Cat 1 chemicals remained similar (accuracy 62.2% with 22.7% sensitivity and 100% specificity). The accuracy of the STE test method to identify No Cat chemicals was 72.5% with 66.2% sensitivity and 100% specificity. Excluding highly volatile chemicals, non-surfactant solids and non-qualified results resulted in an important improvement of the performance of the STE test method (accuracy 96.2% with 81.8% sensitivity and 100% specificity). Furthermore, it seems that solids are more difficult to test in the STE, 71.4% of the solids resulted in unqualified results (solubility issues and/or high variation between independent runs) whereas for liquids 13.2% of the results were not qualified, supporting the restriction of the test method regarding the testing of solids.
Copyright © 2017. Published by Elsevier Ltd.

Entities:  

Keywords:  CON4EI; OECD Test Guideline 491; Ocular irritation; Short Time Exposure (STE) assay

Mesh:

Substances:

Year:  2017        PMID: 28801046     DOI: 10.1016/j.tiv.2017.08.002

Source DB:  PubMed          Journal:  Toxicol In Vitro        ISSN: 0887-2333            Impact factor:   3.500


  2 in total

Review 1.  In vitro reconstructed 3D corneal tissue models for ocular toxicology and ophthalmic drug development.

Authors:  Yulia Kaluzhny; Mitchell Klausner
Journal:  In Vitro Cell Dev Biol Anim       Date:  2021-02-05       Impact factor: 2.416

Review 2.  Same-chemical comparison of nonanimal eye irritation test methods: Bovine corneal opacity and permeability, EpiOcular™, isolated chicken eye, ocular Irritection®, OptiSafe™, and short time exposure.

Authors:  Stewart Lebrun; Linda Nguyen; Sara Chavez; Roxanne Chan; Debby Le; Minh Nguyen; James V Jester
Journal:  Toxicol In Vitro       Date:  2020-12-19       Impact factor: 3.500

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.