Literature DB >> 28798852

Flow reproducibility of whole blood and other bodily fluids in simplified no reaction lateral flow assay devices.

H Li1, D Han1, M A Hegener2, G M Pauletti2, A J Steckl1.   

Abstract

The "no reaction" lateral flow assay (nrLFA) uses a simplified LFA structure with no conjugate pad and no stored reagents. In the nrLFA, the capillary-based transport time or distance is the key indicator, rather than the outcome of a biochemical reaction. Hence, the calibration and reproducibility of the nrLFA device are critical. The capillary flow properties of several membrane types (nitrocellulose, nylon, cellulose acetate, polyethersulfone, and polyvinylidene difluoride) are evaluated. Flow rate evaluations of MilliporeSigma Hi-Flow™ Plus (HF075, HF135 and HF180) nitrocellulose membranes on nrLFA are performed using bodily fluids (whole blood, blood plasma, and artificial sweat). The results demonstrate that fluids with lower viscosity travel faster, and membranes with slower flow rate exhibit higher capability to distinguish fluids with different viscosities. Reproducibility tests of nrLFA are performed on HF075, demonstrating excellent reproducibility. The coefficient of variation for blood coagulation tests performed with the nrLFA using induced coagulation was 5% for the plasma front and 2% for the RBC front. The effects of variation in blood hematocrit and sample volume are also reported. The overall results indicate that the nrLFA approach has a high potential to be commercially developed as a blood monitoring point-of-care device with simple calibration capability and excellent reproducibility.

Entities:  

Year:  2017        PMID: 28798852      PMCID: PMC5533494          DOI: 10.1063/1.4979815

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  43 in total

1.  Three-dimensional paper microfluidic devices assembled using the principles of origami.

Authors:  Hong Liu; Richard M Crooks
Journal:  J Am Chem Soc       Date:  2011-10-17       Impact factor: 15.419

2.  Understanding wax printing: a simple micropatterning process for paper-based microfluidics.

Authors:  Emanuel Carrilho; Andres W Martinez; George M Whitesides
Journal:  Anal Chem       Date:  2009-08-15       Impact factor: 6.986

Review 3.  Paper-based chemical and biological sensors: Engineering aspects.

Authors:  Snober Ahmed; Minh-Phuong Ngoc Bui; Abdennour Abbas
Journal:  Biosens Bioelectron       Date:  2015-09-25       Impact factor: 10.618

4.  Effects of hematocrit and plasma proteins on human blood rheology at low shear rates.

Authors:  S Chien; S Usami; H M Taylor; J L Lundberg; M I Gregersen
Journal:  J Appl Physiol       Date:  1966-01       Impact factor: 3.531

Review 5.  The clinical significance of whole blood viscosity in (cardio)vascular medicine.

Authors:  G A M Pop; D J Duncker; M Gardien; P Vranckx; S Versluis; D Hasan; C J Slager
Journal:  Neth Heart J       Date:  2002-12       Impact factor: 2.380

6.  A versatile valving toolkit for automating fluidic operations in paper microfluidic devices.

Authors:  Bhushan J Toley; Jessica A Wang; Mayuri Gupta; Joshua R Buser; Lisa K Lafleur; Barry R Lutz; Elain Fu; Paul Yager
Journal:  Lab Chip       Date:  2015-03-21       Impact factor: 6.799

Review 7.  Paper-based analytical devices for environmental analysis.

Authors:  Nathan A Meredith; Casey Quinn; David M Cate; Thomas H Reilly; John Volckens; Charles S Henry
Journal:  Analyst       Date:  2016-03-21       Impact factor: 5.227

8.  Detection of shiga toxins by lateral flow assay.

Authors:  Kathryn H Ching; Xiaohua He; Larry H Stanker; Alice V Lin; Jeffery A McGarvey; Robert Hnasko
Journal:  Toxins (Basel)       Date:  2015-04-03       Impact factor: 4.546

9.  Blood viscosity during coagulation at different shear rates.

Authors:  Marco Ranucci; Tommaso Laddomada; Matteo Ranucci; Ekaterina Baryshnikova
Journal:  Physiol Rep       Date:  2014-07-03

10.  Use of portable blood physiology point-of-care devices for basic and applied research on vertebrates: a review.

Authors:  Lauren J Stoot; Nicholas A Cairns; Felicia Cull; Jessica J Taylor; Jennifer D Jeffrey; Félix Morin; John W Mandelman; Timothy D Clark; Steven J Cooke
Journal:  Conserv Physiol       Date:  2014-04-04       Impact factor: 3.079

View more
  7 in total

1.  Engineering a simple lateral flow device for animal blood coagulation monitoring.

Authors:  Hua Li; Daewoo Han; Giovanni M Pauletti; Andrew J Steckl
Journal:  Biomicrofluidics       Date:  2018-01-23       Impact factor: 2.800

Review 2.  Microfluidics geometries involved in effective blood plasma separation.

Authors:  Anamika Maurya; Janani Srree Murallidharan; Atul Sharma; Amit Agarwal
Journal:  Microfluid Nanofluidics       Date:  2022-09-04       Impact factor: 3.090

Review 3.  Evolving Paradigm of Prothrombin Time Diagnostics with Its Growing Clinical Relevance towards Cardio-Compromised and COVID-19 Affected Population.

Authors:  Anubhuti Saha; Ashutosh Bajpai; Vinay Krishna; Shantanu Bhattacharya
Journal:  Sensors (Basel)       Date:  2021-04-09       Impact factor: 3.576

4.  False-positive and false-negative COVID-19 cases: respiratory prevention and management strategies, vaccination, and further perspectives.

Authors:  Dimitra S Mouliou; Konstantinos I Gourgoulianis
Journal:  Expert Rev Respir Med       Date:  2021-04-25       Impact factor: 3.772

5.  Sputum Processing Method for Lateral Flow Immunochromatographic Assays to Detect Coronaviruses.

Authors:  Aram Kang; Minjoo Yeom; Hyekwon Kim; Sun-Woo Yoon; Dae-Gwin Jeong; Hyong-Joon Moon; Kwang-Soo Lyoo; Woonsung Na; Daesub Song
Journal:  Immune Netw       Date:  2021-02-18       Impact factor: 6.303

Review 6.  Toward Next Generation Lateral Flow Assays: Integration of Nanomaterials.

Authors:  Amadeo Sena-Torralba; Ruslan Álvarez-Diduk; Claudio Parolo; Andrew Piper; Arben Merkoçi
Journal:  Chem Rev       Date:  2022-09-06       Impact factor: 72.087

7.  A Simple Distance Paper-Based Analytical Device for the Screening of Lead in Food Matrices.

Authors:  Kasinee Katelakha; Vanida Nopponpunth; Watcharee Boonlue; Wanida Laiwattanapaisal
Journal:  Biosensors (Basel)       Date:  2021-03-22
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.