| Literature DB >> 28798387 |
Yang Wang1, Tzu-Sen Su2, Han-Yan Tsai1, Tzu-Chien Wei3, Yun Chi4.
Abstract
Spiro-OMeTAD with symmetricEntities:
Year: 2017 PMID: 28798387 PMCID: PMC5552831 DOI: 10.1038/s41598-017-08187-4
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1(a) Chemical structures of WY-1, WY-2 and WY-3 compared with Spiro-OMeTAD. (b) Synthetic routes for the studied HTMs.
Electrochemical, photophysical and thermal properties of Spiro-OMeTAD, WY-1, WY-2, and WY-3.
| HTMs | λabs a (nm) |
|
| HOMOd (eV) | LUMOe (eV) |
|
|
|---|---|---|---|---|---|---|---|
| Spiro-OMeTAD | 303, 365, 386 | 3.00 | 0.002 | −5.10 | −2.10 | 452* | 125* |
| WY-1 | 290, 386 | 2.98 | 0.065 | −5.16 | −2.18 | 401 | 122 |
| WY-2 | 269, 386 | 2.98 | 0.065 | −5.16 | −2.18 | 422 | 136 |
| WY-3 | 306, 346, 386 | 2.98 | 0.057 | −5.15 | −2.17 | 427 | 145 |
aMeasured in THF with a concentration of 10−5 M. bCalculated from the absorption onset. cThe oxidative onsets (vs FcH/FcH+) measured by cyclic voltammetry in CH2Cl2. dHOMO = −(E ox + 5.1) eV and LUMO = HOMO + E g,opt.
Figure 2UV-vis absorption spectra of four HTMs measured in solutions (solid line) and thin films (dash line).
Figure 3(a) Structural diagram of the hole-only cell Au/HTM/Au for electrochemical impedance measurement. (b) The typical Nyquist plot of Au/WY-1/Au measured at −0.4 V and its fitting curve using an equivalent circuit (inset). (c) The calculated hole mobility of HTMs vs. applied bias.
Figure 4(a) Cross-section view of representative PSC and (b) energy level diagram of the materials used in the studied PSCs (right).
Figure 5(a–d) Averaged JSC, VOC, FF and PCE of PSCs employed with different HTMs. (e) I-V curves of best-performing PSCs employing the studied HTMs, measured under AM 1.5 G illumination, 100 mW cm−2. (f) IPCE diagrams of the corresponding devices; the total currents derived from the integrated curves are: 18.05 mA/cm2, 18.16 mA/cm2, 18.08 mA/cm2 and 17.32 mA/cm2 for the spiro-OMeTAD, WY-1, WY-2, and WY-3-based device, respectively.
Photovoltaic parameters of PSCs with different hole transporting layer. Photomasks (0.2 × 0.5 cm2) made of thin metal sheet were applied before all measurements.
| Type of BL | JSC (mA/cm2) | VOC (mV) | FF | PCE (%) | Rs (Ω) | HI | |
|---|---|---|---|---|---|---|---|
| Best performing | Spiro-OMeTAD | 19.20 | 1.041 | 0.742 | 14.84 | 32.47 | 0.04 |
| WY-1 | 19.48 | 1.053 | 0.691 | 14.19 | 53.52 | 0.07 | |
| WY-2 | 18.50 | 1.057 | 0.696 | 13.60 | 63.10 | 0.08 | |
| WY-3 | 18.27 | 1.047 | 0.674 | 12.89 | 85.45 | 0.05 | |
| Average* | Spiro-OMeTAD | 19.14 ± 0.46 | 1.046 ± 0.007 | 0.705 ± 0.022 | 14.13 ± 0.57 | 47.96 ± 11.86 | 0.09 ± 0.07 |
| WY-1 | 19.38 ± 0.33 | 1.046 ± 0.005 | 0.662 ± 0.025 | 13.36 ± 0.58 | 51.64 ± 13.09 | 0.09 ± 0.04 | |
| WY-2 | 18.58 ± 0.15 | 1.055 ± 0.003 | 0.560 ± 0.059 | 10.96 ± 1.17 | 89.89 ± 12.57 | 0.39 ± 0.13 | |
| WY-3 | 18.50 ± 0.65 | 1.035 ± 0.003 | 0.556 ± 0.061 | 10.32 ± 1.72 | 100.10 ± 34.37 | 0.35 ± 0.16 | |
The hysteresis index (HI) is defined as (Pmax(forward scan)/Pmax(backward scan))−1, which Pmax is the maximum power in I-V measurement.
*These values were obtained from 6–8 devices.