Literature DB >> 28796904

Kinematic discrimination of ataxia in horses is facilitated by blindfolding.

E Olsen1,2, N FouchÉ3, H Jordan1, T Pfau1, R J Piercy4.   

Abstract

BACKGROUND: Agreement among experienced clinicians is poor when assessing the presence and severity of ataxia, especially when signs are mild. Consequently, objective gait measurements might be beneficial for assessment of horses with neurological diseases.
OBJECTIVES: To assess diagnostic criteria using motion capture to measure variability in spatial gait-characteristics and swing duration derived from ataxic and non-ataxic horses, and to assess if variability increases with blindfolding. STUDY
DESIGN: Cross-sectional.
METHODS: A total of 21 horses underwent measurements in a gait laboratory and live neurological grading by multiple raters. In the gait laboratory, the horses were made to walk across a runway surrounded by a 12-camera motion capture system with a sample frequency of 240 Hz. They were made to walk normally and with a blindfold in at least three trials each. Displacements of reflective markers on head, fetlock, hoof, fourth lumbar vertebra, tuber coxae and sacrum derived from three to four consecutive strides were processed and descriptive statistics, receiver operator characteristics (ROC) to determine the diagnostic sensitivity, specificity and area under the curve (AUC), and correlation between median ataxia grade and gait parameters were determined.
RESULTS: For horses with a median ataxia grade ≥2, coefficient of variation for the location of maximum vertical displacement of pelvic and thoracic distal limbs generated good diagnostic yield. The hoofs of the thoracic limbs yielded an AUC of 0.81 with 64% sensitivity and 90% specificity. Blindfolding exacerbated the variation for ataxic horses compared to non-ataxic horses with the hoof marker having an AUC of 0.89 with 82% sensitivity and 90% specificity. MAIN LIMITATIONS: The low number of consecutive strides per horse obtained with motion capture could decrease diagnostic utility.
CONCLUSIONS: Motion capture can objectively aid the assessment of horses with ataxia. Furthermore, blindfolding increases variation in distal pelvic limb kinematics making it a useful clinical tool.
© 2017 EVJ Ltd.

Entities:  

Keywords:  ataxia; blindfold; coordination; diagnosis; gait analysis; horse; neurological; proprioception

Mesh:

Year:  2017        PMID: 28796904     DOI: 10.1111/evj.12737

Source DB:  PubMed          Journal:  Equine Vet J        ISSN: 0425-1644            Impact factor:   2.888


  3 in total

1.  Outcomes after cervical vertebral interbody fusion using an interbody fusion device and polyaxial pedicle screw and rod construct in 10 horses (2015-2019).

Authors:  Lynn M Pezzanite; Jeremiah T Easley; Rosemary Bayless; Ellison Aldrich; Brad B Nelson; Howard B Seim; Yvette S Nout-Lomas
Journal:  Equine Vet J       Date:  2021-05-03       Impact factor: 2.692

2.  Measurement of Canine Ataxic Gait Patterns Using Body-Worn Smartphone Sensor Data.

Authors:  Daniel Engelsman; Tamara Sherif; Sebastian Meller; Friederike Twele; Itzik Klein; Anna Zamansky; Holger A Volk
Journal:  Front Vet Sci       Date:  2022-08-04

3.  Assessment of static posturography and pedobarography for the detection of unilateral forelimb lameness in ponies.

Authors:  Lidia Pitti; Maarten Oosterlinck; Maria L Díaz-Bertrana; José M Carrillo; Mónica Rubio; Joaquin Sopena; Angelo Santana; José M Vilar
Journal:  BMC Vet Res       Date:  2018-05-02       Impact factor: 2.741

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.