Euddeum Shim1,2, Yusuhn Kang1, Joong Mo Ahn1, Eugene Lee1, Joon Woo Lee1, Joo Han Oh3, Heung Sik Kang1. 1. 1 Department of Radiology, Seoul National University Bundang Hospital, 82, Gumi-ro 173 Beon-gil, Bundanggu, Seongnam-si, Gyeonggi-do, Korea. 2. 2 Present address: Korea University Ansan Hospital, Ansan-si, Gyeonggi-do, Korea. 3. 3 Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, Korea.
Abstract
OBJECTIVE: The objective of this study is to evaluate the effect of the metal artifact reduction algorithm for orthopedic implants (O-MAR) on CT image quality for patients with reverse total shoulder arthroplasty (RTSA), with emphasis placed on the evaluation of bone in the vicinity of prostheses. MATERIALS AND METHODS: Sixty-five patients who underwent CT scanning after RTSA were enrolled in the study. Two radiologists analyzed the images reconstructed with filtered back projection (FBP) with or without O-MAR processing. Images were evaluated to determine the degree of streaking artifacts, the confidence in depicting various structures around the prosthesis, and the presence of pseudolesions. The mean CT number and SD of the selected ROIs placed in the greater tuberosity, glenoid bone, and deltoid muscle were recorded. For measurements from the greater tuberosity and glenoid bone, the frequency with which the measurement met the typical CT number of bone was calculated. RESULTS: O-MAR images showed less metal streak artifact and noise and provided better visualization of the axillary neurovascular bundle compared with FBP images, with a statistically significant difference (p < 0.001 for all). FBP images were found to be statistically significantly better than O-MAR images, offering better visualization of bone cortex, bone trabeculae, and the bone-prosthesis interface (p < 0.001 for all). Scapular pseudonotching was observed on 4.6% of FBP images and 36.9% of O-MAR images. The pseudocemented appearance was noted on 47.7% of O-MAR images but was not seen on FBP images. CONCLUSION: The use of O-MAR improved CT image quality for patients with RTSA in the aspect of metal artifact reduction and soft-tissue profile. However, O-MAR tends to degrade depiction of the bone trabeculae and bone cortex and generate new artifacts, including a pseudocemented appearance and scapular pseudonotching.
OBJECTIVE: The objective of this study is to evaluate the effect of the metal artifact reduction algorithm for orthopedic implants (O-MAR) on CT image quality for patients with reverse total shoulder arthroplasty (RTSA), with emphasis placed on the evaluation of bone in the vicinity of prostheses. MATERIALS AND METHODS: Sixty-five patients who underwent CT scanning after RTSA were enrolled in the study. Two radiologists analyzed the images reconstructed with filtered back projection (FBP) with or without O-MAR processing. Images were evaluated to determine the degree of streaking artifacts, the confidence in depicting various structures around the prosthesis, and the presence of pseudolesions. The mean CT number and SD of the selected ROIs placed in the greater tuberosity, glenoid bone, and deltoid muscle were recorded. For measurements from the greater tuberosity and glenoid bone, the frequency with which the measurement met the typical CT number of bone was calculated. RESULTS: O-MAR images showed less metal streak artifact and noise and provided better visualization of the axillary neurovascular bundle compared with FBP images, with a statistically significant difference (p < 0.001 for all). FBP images were found to be statistically significantly better than O-MAR images, offering better visualization of bone cortex, bone trabeculae, and the bone-prosthesis interface (p < 0.001 for all). Scapular pseudonotching was observed on 4.6% of FBP images and 36.9% of O-MAR images. The pseudocemented appearance was noted on 47.7% of O-MAR images but was not seen on FBP images. CONCLUSION: The use of O-MAR improved CT image quality for patients with RTSA in the aspect of metal artifact reduction and soft-tissue profile. However, O-MAR tends to degrade depiction of the bone trabeculae and bone cortex and generate new artifacts, including a pseudocemented appearance and scapular pseudonotching.
Entities:
Keywords:
CT; arthroplasty; metal artifact; prosthesis; shoulder
Authors: Leonard Sunwoo; Sun-Won Park; Jung Hyo Rhim; Yeonah Kang; Young Seob Chung; Young-Je Son; Soo Chin Kim Journal: J Korean Med Sci Date: 2018-05-02 Impact factor: 2.153
Authors: Ruud H H Wellenberg; Jochen A C van Osch; Henk J Boelhouwers; Mireille A Edens; Geert J Streekstra; Harmen B Ettema; Martijn F Boomsma Journal: Skeletal Radiol Date: 2019-04-24 Impact factor: 2.199