Does ultrasound guidance add accuracy to continuous caudal-epidural catheter placements in neonates and infants?

Vrushali C Ponde1, Vinit V Bedekar1, Ankit P Desai1, Kiran A Puranik1.   

Abstract

BACKGROUND: Caudo-lumbar and caudo-thoracic epidural anesthesia is an established technique that carries a low risk of dural puncture or spinal cord trauma in infants. Traditionally catheter advancement is based on external measurements. However, malpositioning of catheters are known to occur. We hypothesized that caudal-epidural catheters inserted under real-time ultrasound guidance may be more accurate than the accuracy of the measurements traditionally used for their placement.
METHODS: We studied 25 patients, aged 2 days to 5 months, posted for abdominal or thoracic surgery, receiving general anesthesia followed by caudo-epidural continuous block. External measurement defined as the distance from the caudal space and the surgically congruent vertebral level was measured in centimeters with the back gently flexed. Subsequently, a caudo-epidural block was performed in the same position. The epidural catheter insertion was followed under real-time ultrasound guidance till the predetermined vertebral level was reached. The actual length placed under real-time ultrasound scan was defined as the actual length. The high-frequency probe was placed longitudinal and paramedian to the spine. The vertebral level was determined by identifying the lumbosacral junction in longitudinal saggital view and counting the vertebrae up from L5. The catheter length at the skin was compared with the length recorded by external measurement.
RESULTS: The actual length placed under real-time ultrasound scan were consistently longer than the external distance between the caudal space and selected vertebral level. The mean values of ultrasound were higher than the mean values of external measurement with a difference of 4.28 cm. Accuracy was not affected by age or affected by the selected vertebral level in the age group we studied.
CONCLUSION: We conclude that catheters placed under ultrasound guidance are more accurate than the traditional method developed before the advent of ultrasound in young infants.
© 2017 John Wiley & Sons Ltd.

Entities:  

Keywords:  accuracy; epidural catheters; infants; neonates; ultrasonography

Mesh:

Year:  2017        PMID: 28795472     DOI: 10.1111/pan.13212

Source DB:  PubMed          Journal:  Paediatr Anaesth        ISSN: 1155-5645            Impact factor:   2.556


  9 in total

Review 1.  A Review of Regional Anesthesia in Infants.

Authors:  Karen R Boretsky
Journal:  Paediatr Drugs       Date:  2019-12       Impact factor: 3.022

2.  The use of ultrasound guidance for perioperative neuraxial and peripheral nerve blocks in children.

Authors:  Joanne Guay; Santhanam Suresh; Sandra Kopp
Journal:  Cochrane Database Syst Rev       Date:  2019-02-27

3.  On-table extubation in neonates undergoing anoplasty: an experience of anesthetic management on the concept of fast-tracking anesthesia: A pilot study.

Authors:  Yu Cui; Yu Wang; Rong Cao; Kai Liu; Qing-Hua Huang; Bin Liu
Journal:  Medicine (Baltimore)       Date:  2019-01       Impact factor: 1.889

Review 4.  Recent trends in paediatric regional anaesthesia.

Authors:  Vrushali Ponde
Journal:  Indian J Anaesth       Date:  2019-09

5.  Intercostal misplacement of a thoracic epidural catheter discovered during lung cancer surgery: a case report.

Authors:  Izumi Kawagoe; Masakazu Hayashida; Daizoh Satoh; Eiichi Inada
Journal:  JA Clin Rep       Date:  2019-07-11

6.  Postoperative Apnea in a Neonate Following an Epidural Bolus Dose Through a High Thoracic Epidural Catheter.

Authors:  Jay Mathias; Deanna Couser; David P Martin; Joseph D Tobias
Journal:  J Med Cases       Date:  2021-12-02

7.  Caudal catheter placement for repeated epidural morphine doses after neonatal upper abdominal surgery.

Authors:  Anthony M-H Ho; Emma Torbicki; Andrea L Winthrop; Mila Kolar; Julie E Zalan; Gillian MacLean; Glenio B Mizubuti
Journal:  Anaesth Intensive Care       Date:  2022-02-16       Impact factor: 1.669

Review 8.  Caudal and epidural blocks in infants and small children: historical perspective and ultrasound-guided approaches.

Authors:  Hae Keum Kil
Journal:  Korean J Anesthesiol       Date:  2018-08-08

Review 9.  Perioperative Point-of-Care Ultrasound in Children.

Authors:  Karen Boretsky
Journal:  Children (Basel)       Date:  2020-11-06
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.