Literature DB >> 28794846

Icodextrin and spurious hyperglycemia in peritoneal dialysis patients: a hospital-wide attempt to prevent such errors.

Yusuke Asakura1, Keiko Kimura2.   

Abstract

Entities:  

Year:  2017        PMID: 28794846      PMCID: PMC5548953          DOI: 10.4097/kjae.2017.70.4.479

Source DB:  PubMed          Journal:  Korean J Anesthesiol        ISSN: 2005-6419


× No keyword cloud information.
In peritoneal dialysis (PD), a dextrose-containing solution is infused into the peritoneal cavity, and toxic materials are removed by ultrafiltration and diffusive clearance through the peritoneal membrane. PD is used in 2.9% of the approximately 320,000 patients regularly undergoing any form of hemodialysis in Japan. Recently, a non-absorbable carbohydrate (icodextrin; Extraneal™; Baxter Healthcare, Chicago, IL, USA) has been introduced for PD, and more efficient ultrafiltration has been reported. Although icodextrin is usually considered the last step for PD patients with a long dwell, the prevalence of icodextrin use remains unclear. Importantly, serious spurious hyperglycemia perioperatively has been reported with icodextrin [123]. In our facility, 45 patients regularly undergo PD in an outpatient setting. Of these, 14 (31%) patients use icodextrin as the dialysate. Classically, glucose oxidase is used in bedside glucometers. A major drawback is its cross-reactivity with dioxygen, resulting in an underestimation of the blood glucose. As an alternative, soluble quinoprotein glucose dehydrogenase (GDH) with the co-factor pyrroloquinoline quinone (sPQQ-GDH) was developed. This enables measurements without any interference from dioxygen, although low substrate specificity and cross-reactivity with maltose, a metabolite of icodextrin, have been reported. A group of Japanese researchers discovered a novel thermostable heme-containing flavin adenine dinucleotide (FAD)-GDH with high substrate specificity [4]. A FAD-GDH-dependent bedside glucometer is now available commercially, and the list of glucometers is available from the website of Baxter. In May 2015, all of the glucometers in our hospital were replaced and no problems have occurred since then. The cost of the tips for glucometer does not substantially differ from those of sPQQ-GDH glucometer.
  4 in total

1.  Spurious hyperglycaemia and icodextrin in peritoneal dialysis fluid.

Authors:  Stephen G Riley; James Chess; Kieron L Donovan; John D Williams
Journal:  BMJ       Date:  2003-09-13

2.  The danger of using inappropriate point-of-care glucose meters in patients on icodextrin dialysis.

Authors:  N J Perera; P M Stewart; P F Williams; E L Chua; D K Yue; S M Twigg
Journal:  Diabet Med       Date:  2011-10       Impact factor: 4.359

3.  Significant hypoglycemia secondary to icodextrin peritoneal dialysate in a diabetic patient.

Authors:  Henry R Kroll; Thomas R Maher
Journal:  Anesth Analg       Date:  2007-06       Impact factor: 5.108

4.  Novel FAD-dependent glucose dehydrogenase for a dioxygen-insensitive glucose biosensor.

Authors:  Seiya Tsujimura; Shinki Kojima; Kenji Kano; Tokuji Ikeda; Mika Sato; Hirokazu Sanada; Hironori Omura
Journal:  Biosci Biotechnol Biochem       Date:  2006-03       Impact factor: 2.043

  4 in total