Literature DB >> 28786628

ICL-based TDLAS sensor for real-time breath gas analysis of carbon monoxide isotopes.

Ramin Ghorbani, Florian M Schmidt.   

Abstract

We present a compact sensor for carbon monoxide (CO) in air and exhaled breath based on a room temperature interband cascade laser (ICL) operating at 4.69 µm, a low-volume circular multipass cell and wavelength modulation absorption spectroscopy. A fringe-limited (1σ) sensitivity of 6.5 × 10-8 cm-1Hz-1/2 and a detection limit of 9 ± 5 ppbv at 0.07 s acquisition time are achieved, which constitutes a 25-fold improvement compared to direct absorption spectroscopy. Integration over 10 s increases the precision to 0.6 ppbv. The setup also allows measuring the stable isotope 13CO in breath. We demonstrate quantification of indoor air CO and real-time detection of CO expirograms from healthy non-smokers and a healthy smoker before and after smoking. Isotope ratio analysis indicates depletion of 13CO in breath compared to natural abundance.

Entities:  

Year:  2017        PMID: 28786628     DOI: 10.1364/OE.25.012743

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  9 in total

1.  Deep Learning for Type 1 Diabetes Mellitus Diagnosis Using Infrared Quantum Cascade Laser Spectroscopy.

Authors:  Igor Fufurin; Pavel Berezhanskiy; Igor Golyak; Dmitriy Anfimov; Elizaveta Kareva; Anastasiya Scherbakova; Pavel Demkin; Olga Nebritova; Andrey Morozov
Journal:  Materials (Basel)       Date:  2022-04-20       Impact factor: 3.748

2.  Near-infrared tunable diode laser absorption spectroscopy-based determination of carbon dioxide in human exhaled breath.

Authors:  Cunguang Lou; Congrui Jing; Xin Wang; Yuhao Chen; Jiantao Zhang; Kaixuan Hou; Jianquan Yao; Xiuling Liu
Journal:  Biomed Opt Express       Date:  2019-10-02       Impact factor: 3.732

Review 3.  Towards Integrated Mid-Infrared Gas Sensors.

Authors:  Daniel Popa; Florin Udrea
Journal:  Sensors (Basel)       Date:  2019-05-04       Impact factor: 3.576

4.  Highly Sensitive and Precise Analysis of SF6 Decomposition Component CO by Multi-comb Optical-feedback Cavity Enhanced Absorption Spectroscopy with a 2.3 μm Diode Laser.

Authors:  Fu Wan; Feng Zhou; Jin Hu; Pinyi Wang; Jianxin Wang; Weigen Chen; Chengzhi Zhu; Ye Liu
Journal:  Sci Rep       Date:  2019-07-04       Impact factor: 4.379

5.  Towards Interband Cascade lasers on InP Substrate.

Authors:  Krzysztof Ryczko; Janusz Andrzejewski; Grzegorz Sęk
Journal:  Materials (Basel)       Date:  2021-12-22       Impact factor: 3.623

6.  Simultaneous Sensitive Determination of δ13C, δ18O, and δ17O in Human Breath CO2 Based on ICL Direct Absorption Spectroscopy.

Authors:  Ligang Shao; Jiaoxu Mei; Jiajin Chen; Tu Tan; Guishi Wang; Kun Liu; Xiaoming Gao
Journal:  Sensors (Basel)       Date:  2022-02-16       Impact factor: 3.576

7.  Development of a Laser Gas Analyzer for Fast CO2 and H2O Flux Measurements Utilizing Derivative Absorption Spectroscopy at a 100 Hz Data Rate.

Authors:  Mingxing Li; Ruifeng Kan; Yabai He; Jianguo Liu; Zhenyu Xu; Bing Chen; Lu Yao; Jun Ruan; Huihui Xia; Hao Deng; Xueli Fan; Bangyi Tao; Xueling Cheng
Journal:  Sensors (Basel)       Date:  2021-05-13       Impact factor: 3.576

8.  Modeling Pulmonary Gas Exchange and Single-Exhalation Profiles of Carbon Monoxide.

Authors:  Ramin Ghorbani; Anders Blomberg; Florian M Schmidt
Journal:  Front Physiol       Date:  2018-07-30       Impact factor: 4.566

Review 9.  Advances in Mid-Infrared Spectroscopy-Based Sensing Techniques for Exhaled Breath Diagnostics.

Authors:  Ramya Selvaraj; Nilesh J Vasa; S M Shiva Nagendra; Boris Mizaikoff
Journal:  Molecules       Date:  2020-05-09       Impact factor: 4.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.