Nitesh Katta1, Austin B McElroy2, Arnold D Estrada2, Thomas E Milner2. 1. Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, Texas. 2. Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas.
Abstract
BACKGROUND AND OBJECTIVE: Surgical oncology can benefit from specialized tools that enhance imaging and enable precise cutting and removal of tissue without damage to adjacent structures. The combination of high-resolution, fast optical coherence tomography (OCT) co-aligned with a nanosecond pulsed thulium (Tm) laser offers advantages over conventional surgical laser systems. Tm lasers provide superior beam quality, high volumetric tissue removal rates with minimal residual thermal footprint in tissue, enabling a reduction in unwanted damage to delicate adjacent sub-surface structures such as nerves or micro-vessels. We investigated such a combined Tm/OCT system with co-aligned imaging and cutting beams-a configuration we call a "smart laser knife." METHODS: A blow-off model that considers absorption coefficients and beam delivery systems was utilized to predict Tm cut depth, tissue removal rate and spatial distribution of residual thermal injury. Experiments were performed to verify the volumetric removal rate predicted by the model as a function of average power. A bench-top, combined Tm/OCT system was constructed using a 15W 1940 nm nanosecond pulsed Tm fiber laser (500 μJ pulse energy, 100 ns pulse duration, 30 kHz repetition rate) for removing tissue and a swept source laser (1310 ± 70 nm, 100 kHz sweep rate) for OCT imaging. Tissue phantoms were used to demonstrate precise surgery with blood vessel avoidance. Depth imaging informed cutting/removal of targeted tissue structures by the Tm laser was performed. RESULTS: Laser cutting was accomplished around and above phantom blood vessels while avoiding damage to vessel walls. A tissue removal rate of 5.5 mm3 /sec was achieved experimentally, in comparison to the model prediction of approximately 6 mm3 /sec. CONCLUSION: We describe a system that combines OCT and laser tissue modification with a Tm laser. Simulation results of the tissue removal rate using a simple model, as a function of average power, are in good agreement with experimental results using tissue phantoms. Lasers Surg. Med. 50:202-212, 2018.
BACKGROUND AND OBJECTIVE: Surgical oncology can benefit from specialized tools that enhance imaging and enable precise cutting and removal of tissue without damage to adjacent structures. The combination of high-resolution, fast optical coherence tomography (OCT) co-aligned with a nanosecond pulsed thulium (Tm) laser offers advantages over conventional surgical laser systems. Tm lasers provide superior beam quality, high volumetric tissue removal rates with minimal residual thermal footprint in tissue, enabling a reduction in unwanted damage to delicate adjacent sub-surface structures such as nerves or micro-vessels. We investigated such a combined Tm/OCT system with co-aligned imaging and cutting beams-a configuration we call a "smart laser knife." METHODS: A blow-off model that considers absorption coefficients and beam delivery systems was utilized to predict Tm cut depth, tissue removal rate and spatial distribution of residual thermal injury. Experiments were performed to verify the volumetric removal rate predicted by the model as a function of average power. A bench-top, combined Tm/OCT system was constructed using a 15W 1940 nm nanosecond pulsed Tm fiber laser (500 μJ pulse energy, 100 ns pulse duration, 30 kHz repetition rate) for removing tissue and a swept source laser (1310 ± 70 nm, 100 kHz sweep rate) for OCT imaging. Tissue phantoms were used to demonstrate precise surgery with blood vessel avoidance. Depth imaging informed cutting/removal of targeted tissue structures by the Tm laser was performed. RESULTS: Laser cutting was accomplished around and above phantom blood vessels while avoiding damage to vessel walls. A tissue removal rate of 5.5 mm3 /sec was achieved experimentally, in comparison to the model prediction of approximately 6 mm3 /sec. CONCLUSION: We describe a system that combines OCT and laser tissue modification with a Tm laser. Simulation results of the tissue removal rate using a simple model, as a function of average power, are in good agreement with experimental results using tissue phantoms. Lasers Surg. Med. 50:202-212, 2018.
Authors: Nitesh Katta; Daniel Santos; Austin B McElroy; Arnold D Estrada; Glori Das; Mohammad Mohsin; Moses Donovan; Thomas E Milner Journal: Sci Rep Date: 2022-05-19 Impact factor: 4.996
Authors: Nitesh Katta; Arnold D Estrada; Austin B McElroy; Aleksandra Gruslova; Meagan Oglesby; Andrew G Cabe; Marc D Feldman; Ry Declan Fleming; Andrew J Brenner; Thomas E Milner Journal: Theranostics Date: 2019-05-26 Impact factor: 11.556
Authors: Holger Wurm; Patrick Johannes Schuler; Florian Hausladen; René Graesslin; Thomas Karl Hoffmann; Karl Stock; Elisabeth Friederike Reins Journal: Front Surg Date: 2021-12-14
Authors: Konstantin Yashin; Matteo Mario Bonsanto; Ksenia Achkasova; Anna Zolotova; Al-Madhaji Wael; Elena Kiseleva; Alexander Moiseev; Igor Medyanik; Leonid Kravets; Robert Huber; Ralf Brinkmann; Natalia Gladkova Journal: Diagnostics (Basel) Date: 2022-01-28