Literature DB >> 28782094

Comparative SEM analysis of nine F22 aligner cleaning strategies.

Luca Lombardo1, Marco Martini2, Francesca Cervinara3, Giorgio Alfredo Spedicato4, Teresa Oliverio2, Giuseppe Siciliani2.   

Abstract

BACKGROUND: The orthodontics industry has paid great attention to the aesthetics of orthodontic appliances, seeking to make them as invisible as possible. There are several advantages to clear aligner systems, including aesthetics, comfort, chairside time reduction, and the fact that they can be removed for meals and oral hygiene procedures.
METHODS: Five patients were each given a series of F22 aligners, each to be worn for 14 days and nights, with the exception of meal and brushing times. Patients were instructed to clean each aligner using a prescribed strategy, and sections of the used aligners were observed under SEM. One grey-scale SEM image was saved per aligner in JPEG format with an 8-bit colour depth, and a total of 45 measurements on the grey scale ("Value" variable) were made. This dataset was analysed statistically via repeated measures ANOVA to determine the effect of each of the nine cleaning strategies in each of the five patients.
RESULTS: A statistically significant difference in the efficacy of the cleaning strategies was detected. Specifically, rinsing with water alone was significantly less efficacious, and a combination of cationic detergent solution and ultrasonication was significantly more efficacious than the other methods (p < 0.05).
CONCLUSIONS: Of the nine cleaning strategies examined, only that involving 5 min of ultrasonication at 42 k Hz combined with a 0.3% germicidal cationic detergent was observed to be statistically effective at removing the bacterial biofilm from the surface of F22 aligners.

Entities:  

Mesh:

Year:  2017        PMID: 28782094      PMCID: PMC5592163          DOI: 10.1186/s40510-017-0178-9

Source DB:  PubMed          Journal:  Prog Orthod        ISSN: 1723-7785            Impact factor:   2.750


Background

A recent survey by YouGov estimated that 45% of adults are unsatisfied with their smile and that 20% would like to undergo orthodontic treatment to improve their tooth alignment and appearance (www.bos.org.uk/news/NOWYouGovSurvey). Hence, the orthodontics industry has paid great attention to the aesthetics of orthodontic appliances, seeking to make them as invisible as possible [1]. In this context, in 1997, Zia Chishti and Kelsey Wirth developed a barely noticeable aligner system, which they called Invisalign [2]. This system involves the use of a series of customised aligners made of transparent plastic; if worn for a minimum of 20 h per day and replaced every 2 weeks, this system can achieve dental movements of approximately 0.25–0.33 mm per tooth, or group of teeth, per aligner. Dental movement and malocclusion correction stages are planned using virtual planning software 3D (ClinCheck), based on CAD-CAM technology, which is also used to view the final result before treatment is begun [3]. There are several other advantages to clear aligner systems, including aesthetics, comfort, chairside time reduction, and the fact that they can be removed for meals and oral hygiene procedures [4]. However, like any orthodontic device, aligners do contribute to a worsening of oral health due to the accumulation of biofilm. Indeed, biofilm deposition on aligner surfaces has been clearly documented and its impact on oral health requires careful investigation [5, 6]. That being said, there have thus far been very few studies to analyse the impact of clear orthodontic aligners on the oral ecosystem, and their consequent influence on caries formation and decalcification. Nevertheless, it has been shown that adults in active treatment with clear aligners have better periodontal health than those undergoing fixed multibracket appliance treatment, who show worse plaque index, bleeding on probing and periodontal pocketing [7]. This is likely due to the fact that clear aligners can be removed and, therefore, cleaned more effectively to remove dental plaque—a complex community of microorganisms existing on the surface of the teeth in a polymeric matrix of bacterial origin. This biofilm is the cause of many oral diseases, and it has been estimated that roughly 60% of human infections can be ascribed to microbial biofilms [8]. Recent research has shown that a minimal dose of chlorhexidine (0.06%) has no beneficial effect on the oral health of aligner wearers [9], who must keep their appliances in place for 22 h per day in order to ensure good orthodontic outcomes (though it should be mentioned that many patients also keep their aligners on while eating and drinking). While they are being worn, aligners accumulate plaque and a bacterial biofilm forms around the teeth [10]. Aligners also limit the buffering, detergent and remineralising effects of saliva. The biofilm on the enamel is not disturbed by the mechanical action of the lips, cheeks and tongue if an aligner is in place. In fact, one of the main characteristics of the biofilm is the cellular adhesion that occurs between microorganisms and non-exfoliative surfaces. The structure of the biofilm changes according to the bacterial species it is composed of [11-14], but the way in which it is organised protects against the action of chemical and pharmaceutical agents. Indeed, all infections closely linked to the development of the biofilm are highly resistant to non-invasive treatments (i.e. pharmacological) [12, 15, 16]. However, it has been demonstrated that oral bacteria can be destroyed by ultrasonication, via a mechanical phenomenon known as cavitation (bubble formation) [17]. Hence, in a recent study, published by the Journal of Clinical Orthodontics in 2013, Moshiri et al. [10] included this method of cleaning in a list of recommendations they drew up for orthodontists. They also included it in the suggested home hygiene protocol to be given to patients in order to ensure optimal outcomes in aligner therapy. In particular, they advised that patients should refrain from eating with their aligners in, remove any white deposits from their aligners, brush their teeth with a soft brush for two minutes, use dental floss and rinse with fluoride mouthwash in the evening, and always put clean aligners into a clean mouth. For aligner cleaning, they advised the use of either an ultrasonic bath or the Invisalign Cleaning System detergent. However, they cited no specific information regarding the efficacy of these methods. Hence, in order to provide more information on the topic, we set out to conduct a comparative SEM (scanning electron microscopy) study of various appliance cleaning strategies in real-world patients being treated using F22 aligners [18, 19].

Methods

Five patients were scheduled for orthodontic treatment via clear aligners. Silicon impressions were taken of their upper and lower teeth using the dual-impression method. Class 4 plaster (Ortotypo, Lascod®) was used to make the casts, which were then scanned in the lab using an extraoral scanner (SMART, Open Technologies), to obtain STL files and 3D renderings of the patients’ dentition. These were then converted into resin models using a laser printer (EnvisionTEC ULTRA 3SP), which were in turn used as moulds for a series of nine F22 aligners [18, 19], formed out of thermoplastic polyurethane (TPU), after isolating them with Isofolan sheets. Each aligner in the series was worn by the patient for 14 days, being removed only at meals and during oral hygiene procedures. Patients were instructed to clean the nine aligners using the following strategies, respectively: Rinsing with water Immersion in water in a sonic bath Immersion in water in an ultrasonic bath Immersion in water and anionic detergent Immersion in water and anionic detergent in a sonic bath Immersion in water and anionic detergent in an ultrasonic bath Immersion in water and cationic detergent Immersion in water and cationic detergent in a sonic bath Immersion in water and cationic detergent in an ultrasonic bath The sonic device used (TCS Fresh®) for aligners 2, 5 and 8 in the series features a bath in which to immerse the aligner and vibrates at a frequency 5800 Hz, while the ultrasonic device (iSonic F3900®) used for aligners 3, 6 and 9, though very similar in structure, vibrates at a frequency of 42,000 Hz. According to the manufacturer’s instructions, the anionic detergent used (TCS Fresh®) for aligners 4, 5 and 6 should not be used directly in the mouth or for more than 7 days. It is sold in powder form in 1.75-g packets, each to be dissolved in 100 ml of water. Similarly, direct contact with the cationic detergent (benzalkonium chloride, Caelo®) used with aligners 7, 8 and 9, sold in a 0.3% aqueous solution, should also be avoided, as it is toxic to the skin and upon ingestion, and can irritate the skin and eyes. Before replacing in the mouth, therefore, patients were instructed to thoroughly rinse their aligners under running water to remove any trace of detergent. Aligner cleaning times for each strategy were standardised at 5 min, and each disinfection procedure was performed by the patient at home twice a day. After being worn for 14 days, the aligners were returned to the orthodontist for analysis. Specifically, a 6 × 6-mm section of each aligner was cut from the vestibular surface of the upper right first premolar area (the transition zone between anterior and posterior sectors). Each section was immediately conserved in glutaraldehyde, and the aligner sealed in a plastic bag; both the container of glutaraldehyde were labelled with the same ID (Fig. 1). The preserved aligner sections were dried and gilded at the University of Ferrara Microscopy Lab and then observed under SEM. The scanning electron microscope was focused on the centre of each sample, which was enlarged 10 thousand times. The resulting SEM images were saved in JPEG format on an 8-bit colour-depth grey scale. A histogram of the grey-scale attributes was created for each SEM image to provide a graphical representation of the number of pixels in the image for each grey on the scale.
Fig. 1

Processing a used aligner before sending to the lab

Processing a used aligner before sending to the lab The dataset composed of the 45 observations, representing the measures on the grey scale (Value variable) of the nine different cleaning methods (one per aligner) used by the five patients, was then subjected to statistical analysis. Repeated-measures ANOVA was used to determine whether the Value variable was influenced by the different aligner/cleaning strategy combinations. The software R nlme [20] was used for ANOVA modelling, specifying “cleaning strategy” as a “within subject” variable, and the patient as a random factor. In order to identify statistically significant differences between aligner and cleaning strategy combinations, a post hoc analysis was performed using Multcomp software [21]. This analysis showed that the differences between the effects of distinct cleaning strategy pairs were statistically equal to zero.

Results

The SEM image analysis (Table 1) and statistical analysis summarising the Value measurements per aligner/cleaning strategy (Table 2) show that the cleaning strategy variable does have a statistically significant effect on the Value (p value zero), i.e. the “cleanliness” of the aligner. However, as shown in Table 3 and Fig. 2, only the first and ninth cleaning strategies (rinsing with water and immersion in water and cationic detergent in an ultrasonic bath, respectively) were significantly different from the others, the former being significantly less efficacious, and the latter being significantly more efficacious.
Table 1

The mean grey values of each image of aligners cleaned by each of the nine cleaning strategies in each of the five patients, showing the mean calculated for each cleaning method

Method 1Method 2Method 3Method 4Method 5Method 6Method 7Method 8Method 9
PT 1143.618126.714111.379112.007109.033124.756132.793117.48181.492
PT 2154.730115.470111.380109.226109.219132.481131.457114.48683.033
PT 3140.032107.871112.168140.546133.622107.512125.045129.60484.454
PT 4163.922114.175131.064108.467145.483138.692117.787119.59880.219
PT 5147.972122.249134.454130.679141.776134.050108.033116.97873.534
MEAN150.055117.296120.089120.185127.827127.498123.023119.62980.546
Table 2

Summarises the values for each cleaning strategy: number of observations, mean grey value and standard deviation

MethodLengthMeanSD
15150.19.492
25117.37.334
35120.111.63
45120.214.57
55127.817.6
65127.512.25
7512310.28
85119.65.865
9580.554.232
Table 3

A p value of zero indicates that the ANOVA test used is significant and refutes the hypothesis that all methods tested are similar

numDFdenDF F value p value
(Intercept)13253170
Method83213.130.00000003592
Fig. 2

Post hoc analysis of cleaning strategy pairs

The mean grey values of each image of aligners cleaned by each of the nine cleaning strategies in each of the five patients, showing the mean calculated for each cleaning method Summarises the values for each cleaning strategy: number of observations, mean grey value and standard deviation A p value of zero indicates that the ANOVA test used is significant and refutes the hypothesis that all methods tested are similar Post hoc analysis of cleaning strategy pairs

Discussion

All aligner cleaning strategies did reduce the bacterial biofilm on the surface of our aligner samples, with the exception of rinsing under tap-water alone. However, our data also show that the most efficacious strategy tested was cationic detergent combined with ultrasonication. Our comparative results also appear to confirm the literature reports that the only way to kill bacteria via low-intensity ultrasound is by combining it with a bactericidal agent [22, 23]. Indeed, we clearly show that a cationic detergent alone is not sufficient to eliminate the bacterial biofilm from the surface of aligners, despite its bactericidal properties, which have been demonstrated in other studies [24, 25]. Similarly, 5 min of 42,000 Hz ultrasound alone was not sufficient to remove the biofilm [26], and only a combination of the two methods proved useful in this regard according to our statistical analysis. Indeed, even a brief glance at the SEM images for each of the aligners reveals evident bacterial colonisation of each, with the exception of those cleaned by the ninth strategy, which combined an ultrasonic bath with a cationic bactericide. These compare very favourably not only with those rinsed with water alone, which show visible layers of abundant bacteria organised into a biofilm, but also those cleaned using the other strategies (2–8), which show variable levels of bacterial proliferation. As the SEM image of the unused aligner (Fig. 3) is much darker than that cleaned by the first method (Fig. 4)—rinsing with water alone—we decided to numerically quantify the visible biofilm on the aligner sections using grey-scale analysis, taking a mean of the levels of grey in the images of the aligners cleaned by each method. The cleaner aligners are darker in colour and show grey-scale levels closer to that of the unused aligner, i.e. 61.924, which appears totally dark. Bacterial proliferation on the surface of the aligner, on the other hand, makes them appear lighter in colour, and the multi-layer biofilm causes the mean level of grey to differ considerably from that of the clean TPU of the unused aligner. By statistically analysing this data, we were able to confirm that there was indeed a statistically significant relationship between the SEM grey-scale levels and the cleanliness of the aligner sections.
Fig. 3

Unused aligner

Fig. 4

Aligner cleaned by rinsing with water alone (method 1)

Unused aligner Aligner cleaned by rinsing with water alone (method 1) Careful SEM analysis of the aligner sections cleaned via the ninth method (Fig. 5), i.e. ultrasonic bath and cationic detergent, reveal interesting points regarding their surface characteristics. The first is that the TPU material itself bears clear striations, an indication of its hydrophilic status [25, 26], and its absorption of water. The second visible feature is related to the method of cleaning used; the surface of the aligner bears signs of pitting. This is likely an effect of ultrasonic cavitation and is visible thanks to the lack of bacterial proliferation. It demonstrates that the mechanical turbulence generated by the acoustic waves, the continual formation and rupture of tiny bubbles, releases sufficient energy to damage not only bacterial cell walls [27] but also the surface of thermoplastic polyurethane.
Fig. 5

Aligner cleaned by method 9 shows clear signs of water absorption and ultrasonic cavitation

Aligner cleaned by method 9 shows clear signs of water absorption and ultrasonic cavitation In order to directly compare these findings with those in the literature in any meaningful way, we would need to rely on studies conducted using the same methods for analysing the aligner surfaces and counting the bacterial colonies. However, there is great variability in the literature in terms of these factors, and in any case, our design prevented us from providing precise bacterial counts for comparison. Nevertheless, our findings generally confirm those of Torlak and Sert [28] and Mermillod-Blondin et al. [29] that the association between a germicidal detergent and ultrasonication is able to reduce the bacterial load on the surfaces analysed.

Conclusions

Of the nine cleaning strategies examined, only that involving 5 min of ultrasound treatment at 42 kHz combined with a 0.3% solution of the germicidal cationic detergent benzalkonium chloride was statistically observed to be effective at removing the bacterial biofilm from the surface of used F22 TPU aligners [18, 19] (p < 0.05).
  25 in total

1.  Spatial Organization of Microbial Biofilm Communities.

Authors: 
Journal:  Microb Ecol       Date:  2000-08       Impact factor: 4.552

Review 2.  A review of therapeutic ultrasound: biophysical effects.

Authors:  K G Baker; V J Robertson; F A Duck
Journal:  Phys Ther       Date:  2001-07

3.  Invisalign A to Z.

Authors:  Benson H Wong
Journal:  Am J Orthod Dentofacial Orthop       Date:  2002-05       Impact factor: 2.650

Review 4.  Microbial biofilm modulation by ultrasound: current concepts and controversies.

Authors:  Matteo Erriu; Cornelio Blus; Serge Szmukler-Moncler; Silvano Buogo; Raffaello Levi; Giulio Barbato; Daniele Madonnaripa; Gloria Denotti; Vincenzo Piras; Germano Orrù
Journal:  Ultrason Sonochem       Date:  2013-05-28       Impact factor: 7.491

Review 5.  Simultaneous inference in general parametric models.

Authors:  Torsten Hothorn; Frank Bretz; Peter Westfall
Journal:  Biom J       Date:  2008-06       Impact factor: 2.207

6.  Stress relaxation properties of four orthodontic aligner materials: A 24-hour in vitro study.

Authors:  Luca Lombardo; Elisa Martines; Valentina Mazzanti; Angela Arreghini; Francesco Mollica; Giuseppe Siciliani
Journal:  Angle Orthod       Date:  2016-06-17       Impact factor: 2.079

Review 7.  Dental plaque as a biofilm.

Authors:  P D Marsh; D J Bradshaw
Journal:  J Ind Microbiol       Date:  1995-09

8.  Halitosis, oral health and quality of life during treatment with Invisalign(®) and the effect of a low-dose chlorhexidine solution.

Authors:  Isabelle Schaefer; Bert Braumann
Journal:  J Orofac Orthop       Date:  2010-11-17       Impact factor: 1.938

9.  Biopolymer and water dynamics in microbial biofilm extracellular polymeric substance.

Authors:  Jennifer A Hornemann; Anna A Lysova; Sarah L Codd; Joseph D Seymour; Scott C Busse; Philip S Stewart; Jennifer R Brown
Journal:  Biomacromolecules       Date:  2008-07-30       Impact factor: 6.988

10.  Invisible orthodontics part 1: invisalign.

Authors:  Ovais H Malik; Ailbhe McMullin; David T Waring
Journal:  Dent Update       Date:  2013-04
View more
  4 in total

1.  The force effects of two types of polyethylene terephthalate glyc-olmodified clear aligners immersed in artificial saliva.

Authors:  Biao Xiang; Xingxing Wang; Gang Wu; Yichen Xu; Menghan Wang; Yanjing Yang; Qingyu Wang
Journal:  Sci Rep       Date:  2021-05-12       Impact factor: 4.379

Review 2.  Clear Aligners: Between Evolution and Efficiency-A Scoping Review.

Authors:  Alessandra Putrino; Ersilia Barbato; Gabriella Galluccio
Journal:  Int J Environ Res Public Health       Date:  2021-03-11       Impact factor: 3.390

Review 3.  Cleaning and Disinfection Protocols for Clear Orthodontic Aligners: A Systematic Review.

Authors:  Carole Charavet; Zoé Gourdain; Léa Graveline; Laurence Lupi
Journal:  Healthcare (Basel)       Date:  2022-02-10

4.  Assessment of the Bacterial Loads of Vacuum-Thermoformed Removable Retainers (VTRR) in Patients under Retention Therapy: A Randomized Clinical Trial.

Authors:  Andrea Butera; Simone Gallo; Maurizio Pascadopoli; Beatrice Sfondrini; Mario Alovisi; Anand Marya; Giulia Stablum; Andrea Scribante
Journal:  Healthcare (Basel)       Date:  2022-07-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.