Literature DB >> 28780359

Change regularity of water quality parameters in leakage flow conditions and their relationship with iron release.

Jingqing Liu1, Huabin Shentu1, Huanyu Chen2, Ping Ye3, Bing Xu3, Yifu Zhang1, Hamid Bastani1, Hongxi Peng1, Lei Chen4, Tuqiao Zhang1.   

Abstract

The long-term stagnation in metal water supply pipes, usually caused by intermittent consumption patterns, will cause significant iron release and water quality deterioration, especially at the terminus of pipelines. Another common phenomenon at the terminus of pipelines is leakage, which is considered helpful by allowing seepage of low-quality drinking water resulting from long-term stagnation. In this study, the effect of laminar flow on alleviating water quality deterioration under different leakage conditions was investigated, and the potential thresholds of the flow rate, which can affect the iron release process, were discussed. Based on a galvanized pipe and ductile cast iron pipe pilot platform, which was established at the terminus of pipelines, this research was carried out by setting a series of leakage rate gradients to analyze the influence of different leakage flow rates on iron release, as well as the relationship with chemical and biological parameters. The results showed that the water quality parameters were obviously influenced by the change in flow velocity. Water quality was gradually improved with an increase in flow velocity, but its change regularity reflected a diversity under different flow rates (p < 0.05). The iron release was remarkably correlated to the redox potential, dissolved oxygen, pH, iron-oxidized bacteria and sulfate-reducing bacteria. The cumulative total iron release (r = 0.587, p < 0.05) and total iron release rate (r = 0.71, p < 0.022) were significantly influenced by the changes in flow velocity. In short, they tended first to increase and then to decrease with an increasing flow velocity with the threshold as approximately 40% of the critical laminar flow velocity (1.16 × 10-3 m/s). For the pipes at the terminus of the drinking water distribution system, when the bulk water was at the critical laminar flow velocity, the concentration of total iron, the quantity and rate of total iron release remain relatively in an ideal and safe situation.
Copyright © 2017. Published by Elsevier Ltd.

Entities:  

Keywords:  Critical laminar flow velocity; Iron release; Leakage flow rate; Metal pipe; Water quality index

Mesh:

Substances:

Year:  2017        PMID: 28780359     DOI: 10.1016/j.watres.2017.07.027

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  3 in total

1.  The dependence of chlorine decay and DBP formation kinetics on pipe flow properties in drinking water distribution.

Authors:  Yingying Zhao; Y Jeffrey Yang; Yu Shao; Jill Neal; Tuqiao Zhang
Journal:  Water Res       Date:  2018-04-27       Impact factor: 11.236

2.  Correlation of extracellular polymeric substances and microbial community structure in denitrification biofilm exposed to adverse conditions.

Authors:  Shuo Wang; Liling Zhi; Wei Shan; Hui Lu; Qiao Xu; Ji Li
Journal:  Microb Biotechnol       Date:  2020-07-23       Impact factor: 5.813

3.  Fish-scale-derived carbon dots as efficient fluorescent nanoprobes for detection of ferric ions.

Authors:  Yi Zhang; Zhiyong Gao; Xue Yang; Jiuli Chang; Ziyan Liu; Kai Jiang
Journal:  RSC Adv       Date:  2019-01-09       Impact factor: 4.036

  3 in total