Frondlike Synovitis on MRI and Correlation With Polyethylene Surface Damage of Total Knee Arthroplasty.

Angela E Li1, Christine C Johnson2, Darryl B Sneag1, Chelsea N Koch3, Kara Fields4, Theodore T Miller1, Timothy M Wright3, Douglas E Padgett2, Hollis G Potter1.   

Abstract

OBJECTIVE: The purpose of this study is to determine the association between polyethylene surface damage and the severity of frondlike hypertrophied synovitis, joint distention, capsular thickness, and osteolysis on MRI compared with other patient factors. Another goal of this study is to ascertain the interobserver reliability in MRI evaluation of synovitis.
MATERIALS AND METHODS: MR images of 61 patients who had undergone revision total knee arthroplasty (TKA) were retrospectively reviewed. The two MRI reviewers were blinded to clinical and retrieval data. The retrieved polyethylene tibial inserts were graded to determine the severity of surface damage. The association of MRI features with surface damage was assessed using Spearman correlation coefficients and multiple linear regression. Interobserver reliability was assessed using the kappa statistic.
RESULTS: Correlations were moderate between the surface damage score and MRI synovitis severity (r = 0.46; p < 0.001) and joint distention (r = 0.41; p = 0.001). Multiple linear regression showed that the MRI synovitis score (p = 0.045), male sex (p = 0.007), body mass index (p = 0.041), and the time since implantation (p < 0.0001) predicted the surface damage score. Substantial interobserver agreement was shown for MRI grading of synovitis (κ = 0.72; 95% CI, 0.65-0.80).
CONCLUSION: The magnitude of frondlike hypertrophied synovitis on MRI is significantly associated with polyethylene surface damage in patients who undergo revision TKA. The finding of severe frondlike synovitis on MR images of patients with TKA should raise the possibility of polyethylene surface damage. However, time since implantation is a stronger predictor of surface damage.

Entities:  

Keywords:  arthroplasty; knee MRI; polyethylene; prosthesis failure; replacement; synovitis

Mesh:

Substances:

Year:  2017        PMID: 28777663     DOI: 10.2214/AJR.16.17443

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  4 in total

1.  What Is the Impact of Automated Synovial Cell Counting on Different Aseptic Causes and Periprosthetic Conditions Associated With Revision THA?

Authors:  Hussein Abdelaziz; Alaa Aljawabra; Markus Rossmann; Calvin Shum Tien; Mustafa Citak; Till Orla Klatte; Thorsten Gehrke
Journal:  Clin Orthop Relat Res       Date:  2021-12-01       Impact factor: 4.176

2.  MRI as Diagnostic Modality for Analyzing the Problematic Knee Arthroplasty: A Systematic Review.

Authors:  Femke F Schröder; Corine E Post; Frank-Christiaan B M Wagenaar; Nico Verdonschot; Rianne M H A Huis In't Veld
Journal:  J Magn Reson Imaging       Date:  2019-07-22       Impact factor: 4.813

3.  Pathological analysis of periprosthetic soft tissue and modes of failure in revision total joint arthroplasty patients.

Authors:  Patrick Bettiol; Alec Egan; Cameron Cox; Eric Wait; George Brindley
Journal:  SAGE Open Med       Date:  2021-09-22

4.  The diagnostic potential of low-field MRI in problematic total knee arthroplasties - a feasibility study.

Authors:  Femke F Schröder; Corine E Post; Sjoerd M van Raak; Frank F J Simonis; Frank-Christiaan B M Wagenaar; Rianne M H A Huis In't Veld; Nico Verdonschot
Journal:  J Exp Orthop       Date:  2020-07-31