Comment on Montagna, et al. Evaluation of Legionella air contamination in healthcare facilities by different sampling methods: An Italian multicenter study. Int. J. Environ. Res. Public Health 2017, 14, 670.

Samuel Collins1, Jimmy Walker2.   

Abstract

Entities:  

Keywords:  Legionella; Legionnaires’ disease; aerosol; detection; risk assessment

Mesh:

Year:  2017        PMID: 28777305      PMCID: PMC5580580          DOI: 10.3390/ijerph14080876

Source DB:  PubMed          Journal:  Int J Environ Res Public Health        ISSN: 1660-4601            Impact factor:   3.390


× No keyword cloud information.

Introduction

In their recent article, Montagna et al. describe a multicenter study investigating the presence of Legionella in water and air samples of Italian healthcare facilities [1]. This is an interesting study that highlights some important gaps in our basic understanding of Legionella. One of the limitations of the study regarded the lack of information on the tap outlets (e.g., design of tap, flow rates, temperature of the water) and the bathrooms (ambient temperature, humidity, air movements, etc.) as these factors can influence aerosols produced and may facilitate the interpretation of aerosol data. For future studies it may be advantageous to characterise the aerosols produced by these outlets, using for example an aerodynamic particle sizer (APS) [2]. Furthermore, caution should be advised as some of the conclusions from the culture data are based on the detection of just 1 colony forming unit (CFU)/m3 of air (or 1 CFU per hour of sampling). Comparison of this data to the number of genomic units (GU) detected in the air by Coriolis® sampling is difficult, as the data is not presented as GU/m3. It would have been more appropriate to compare the number of GU in the water with the number of GU in the air to give a better ‘estimation’ of the emission factor. Nonetheless, the relative inability to isolate viable Legionella from the air is interesting and reinforces previous findings [3,4], including our own failures to culture airborne Legionella from both water sources [5] and compost (unpublished data). Similarly, the only successful method in these studies was liquid impingement using an all glass-cyclone sampler combined with quantitative polymerase chain reaction (qPCR). So, why is Legionella difficult to culture from the air? The authors rightly state that factors such as water chemistry, the stress of aerosolisation, and the method of sampling can influence the recovery of viable Legionella. Furthermore, it has been shown that a high concentration of Legionella (>300 CFU/mL) in shower water is required to detect Legionella in the air [6]. This may go some way to explaining why viable airborne Legionella was infrequently detected at low concentrations in this study. Perhaps the low recovery of viable Legionella from the air is a factor in the sporadic nature of Legionnaires’ disease? However, there are also significant gaps in our understanding of Legionella. Quite simply, for a respiratory pathogen that is predominantly transmitted through aerosols, we have a poor understanding of Legionella in the aerosol state. Several key questions remain and should be research priorities in light of a globally increasing incidence of Legionnaires’ disease and an increasingly elderly and immunocompromised population: What forms of Legionella are present in aerosols from different sources? Are they viable or infectious? How is Legionella partitioned in the aerosol state; e.g., how much is associated with respirable particles <5 µm in size? What impact does the water system/outlet have on this? What is the relationship between the amount of Legionella in the water and the amount of respirable Legionella in the air? Do some Legionella (e.g., sequence types commonly associated with human disease) survive better in the air compared to others? Do amoeba and/or amoeba cysts play a role in aerosol survival and airborne transmission of Legionella? How far can aerosols travel in the built environment? As the authors state, Legionella air sampling could inform quantitative microbial risk assessments (QMRA), improve our understanding of the risks posed by particular water systems, and inform mitigation measures. That said, there is a requirement for improved detection and characterisation of Legionella-containing aerosols and controlled and reproducible experiments on laboratory models and importantly, real-world systems. Until these advances are made, it is clear that the most appropriate method for controlling the risk from Legionella is to control its presence in the water, eliminating the key risk factors and limiting the numbers capable of being disseminated.
  5 in total

1.  Detection of airborne Legionella while showering using liquid impingement and fluorescent in situ hybridization (FISH).

Authors:  Magali Deloge-Abarkan; Thi-Lan Ha; Enric Robine; Denis Zmirou-Navier; Laurence Mathieu
Journal:  J Environ Monit       Date:  2006-11-10

2.  Occurrence of Legionella in UK household showers.

Authors:  Samuel Collins; David Stevenson; Allan Bennett; Jimmy Walker
Journal:  Int J Hyg Environ Health       Date:  2016-12-02       Impact factor: 5.840

3.  Legionella pneumophila in aerosols from shower baths.

Authors:  P J Dennis; A E Wright; D A Rutter; J E Death; B P Jones
Journal:  J Hyg (Lond)       Date:  1984-10

4.  Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

Authors:  Maria Teresa Montagna; Osvalda De Giglio; Maria Luisa Cristina; Christian Napoli; Claudia Pacifico; Antonella Agodi; Tatjana Baldovin; Beatrice Casini; Maria Anna Coniglio; Marcello Mario D'Errico; Santi Antonino Delia; Maria Grazia Deriu; Marco Guida; Pasqualina Laganà; Giorgio Liguori; Matteo Moro; Ida Mura; Francesca Pennino; Gaetano Privitera; Vincenzo Romano Spica; Silvia Sembeni; Anna Maria Spagnolo; Stefano Tardivo; Ida Torre; Federica Valeriani; Roberto Albertini; Cesira Pasquarella
Journal:  Int J Environ Res Public Health       Date:  2017-06-22       Impact factor: 3.390

5.  Necessity and effect of combating Legionella pneumophila in municipal shower systems.

Authors:  Ragnhild Wiik; Anne Vatland Krøvel
Journal:  PLoS One       Date:  2014-12-09       Impact factor: 3.240

  5 in total
  1 in total

1.  Response to Comments on Montagna et al. "Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study" Int. J. Environ. Res. Public Health 2017, 14, 670.

Authors:  Maria Teresa Montagna; Osvalda De Giglio; Antonella Agodi; Cesira Pasquarella
Journal:  Int J Environ Res Public Health       Date:  2017-08-11       Impact factor: 3.390