Literature DB >> 28777063

Comprehensive biomechanical analysis of three reconstruction techniques following total sacrectomy: an in vitro human cadaveric model.

Mohamed Macki1, Rafael De la Garza-Ramos2, Ashley A Murgatroyd3, Kenneth P Mullinix3, Xiaolei Sun3, Bryan W Cunningham3, Brandon A McCutcheon4, Mohamad Bydon4, Ziya L Gokaslan5.   

Abstract

OBJECTIVE Aggressive sacral tumors often require en bloc resection and lumbopelvic reconstruction. Instrumentation failure and pseudarthrosis remain a clinical concern to be addressed. The objective in this study was to compare the biomechanical stability of 3 distinct techniques for sacral reconstruction in vitro. METHODS In a human cadaveric model study, 8 intact human lumbopelvic specimens (L2-pelvis) were tested for flexion-extension range of motion (ROM), lateral bending, and axial rotation with a custom-designed 6-df spine simulator as well as axial compression stiffness with the MTS 858 Bionix Test System. Biomechanical testing followed this sequence: 1) intact spine; 2) sacrectomy (no testing); 3) Model 1 (L3-5 transpedicular instrumentation plus spinal rods anchored to iliac screws); 4) Model 2 (addition of transiliac rod); and 5) Model 3 (removal of transiliac rod; addition of 2 spinal rods and 2 S-2 screws). Range of motion was measured at L4-5, L5-S1/cross-link, L5-right ilium, and L5-left ilium. RESULTS Flexion-extension ROM of the intact specimen at L4-5 (6.34° ± 2.57°) was significantly greater than in Model 1 (1.54° ± 0.94°), Model 2 (1.51° ± 1.01°), and Model 3 (0.72° ± 0.62°) (p < 0.001). Flexion-extension at both the L5-right ilium (2.95° ± 1.27°) and the L5-left ilium (2.87° ± 1.40°) for Model 3 was significantly less than the other 3 cohorts at the same level (p = 0.005 and p = 0.012, respectively). Compared with the intact condition, all 3 reconstruction groups statistically significantly decreased lateral bending ROM at all measured points. Axial rotation ROM at L4-5 for Model 1 (2.01° ± 1.39°), Model 2 (2.00° ± 1.52°), and Model 3 (1.15° ± 0.80°) was significantly lower than the intact condition (5.02° ± 2.90°) (p < 0.001). Moreover, axial rotation for the intact condition and Model 3 at L5-right ilium (2.64° ± 1.36° and 2.93° ± 1.68°, respectively) and L5-left ilium (2.58° ± 1.43° and 2.93° ± 1.71°, respectively) was significantly lower than for Model 1 and Model 2 at L5-right ilium (5.14° ± 2.48° and 4.95° ± 2.45°, respectively) (p = 0.036) and L5-left ilium (5.19° ± 2.34° and 4.99° ± 2.31°) (p = 0.022). Last, results of the axial compression testing at all measured points were not statistically different among reconstructions. CONCLUSIONS The addition of a transverse bar in Model 2 offered no biomechanical advantage. Although the implementation of 4 iliac screws and 4 rods conferred a definitive kinematic advantage in Model 3, that model was associated with significantly restricted lumbopelvic ROM.

Entities:  

Keywords:  BMD = bone mineral density; EZ = elastic zone; Galveston L-rod; LED = light-emitting diode; MGR = modified Galveston reconstruction; NZ = neutral zone; ROM = range of motion; SIJ = sacroiliac joint; TFR = triangular frame reconstruction; biomechanics; lumbopelvic; sacral reconstruction; sacrectomy; sacrum

Mesh:

Year:  2017        PMID: 28777063     DOI: 10.3171/2017.2.SPINE161128

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  3 in total

1.  Total sacrectomy with a combined antero-posterior surgical approach for malignant sacral tumours.

Authors:  Feifei Pu; Zhicai Zhang; Baichuan Wang; Qiang Wu; Jianxiang Liu; Zengwu Shao
Journal:  Int Orthop       Date:  2021-03-25       Impact factor: 3.075

2.  The impact of different artificial disc heights during total cervical disc replacement: an in vitro biomechanical study.

Authors:  Xiao-Fei Wang; Yang Meng; Hao Liu; Bei-Yu Wang; Ying Hong
Journal:  J Orthop Surg Res       Date:  2021-01-06       Impact factor: 2.359

3.  Biomechanical Analysis of the Tuning Fork Plate Versus Dual Pelvic Screws in a Sacrectomy Model: A Finite Element Study.

Authors:  Amin Joukar; Jwalant Mehta; Vijay K Goel; David S Marks
Journal:  Global Spine J       Date:  2021-02-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.