| Literature DB >> 28772439 |
Raúl Mateos1, Raúl M Alonso2, Adrián Escapa3,4, Antonio Morán5.
Abstract
The development and practical implementation of bioelectrochemical systems (BES) requires an in-depth characterisation of their components. The electrodes, which are critical elements, are usually built from carbon-based materials due to their high specific surface area, biocompatibility and chemical stability. In this study, a simple methodology to electrochemically characterise carbon-based electrodes has been developed, derived from conventional electrochemical analyses. Combined with classical electrochemical theory and the more innovative fractal geometry approach, our method is aimed at comparing and characterising the performance of carbon electrodes through the determination of the electroactive surface and its fractal dimension. Overall, this methodology provides a quick and easy method for the screening of suitable electrode materials to be implemented in BES.Entities:
Keywords: bioelectrochemical systems; carbon-based electrodes; electroactive area; fractal dimension; scale up
Year: 2017 PMID: 28772439 PMCID: PMC5344576 DOI: 10.3390/ma10010079
Source DB: PubMed Journal: Materials (Basel) ISSN: 1996-1944 Impact factor: 3.623
Figure 10.5 cm-thick carbon felt (a); 0.25 cm-thick carbon felt (b); carbon paper (c); and brush (d) electrodes.
Material specification and coding.
| Code | Material | Size | Apparent Surface (cm2) |
|---|---|---|---|
| TF1 | Thick carbon felt | 1 cm width; 1 cm length; 5 mm thickness | 1 |
| TF2 | Thick carbon felt | 1.5 cm width; 1.5 cm length; 5 mm thickness | 2.25 |
| TF3 | Thick carbon felt | 2 cm width; 2 cm length; 5 mm thickness | 4 |
| FF1 | Fine carbon felt | 1 cm width; 1 cm length; 2 mm thickness | 1 |
| FF2 | Fine carbon felt | 1.5 cm width; 1.5 cm length; 2 mm thickness | 2.25 |
| FF3 | Fine carbon felt | 2 cm width; 2 cm length; 2 mm thickness | 4 |
| P1 | Carbon paper | 1 cm width; 1 cm length | 1 |
| P2 | Carbon paper | 1.5 cm width; 1.5 cm length | 2.25 |
| P3 | Carbon paper | 2 cm width; 2 cm length | 4 |
| B1 | Carbon brush | 1 cm diameter; 2.5 cm height | 1.87 |
| B2 | Carbon brush | 2 cm diameter; 3 cm height | 5.33 |
Figure 2Carbon paper electrode with air bubbles after pre-treatment.
Figure 3(a) Cell diagram (WE: working electrode; RE: reference electrode; CE: counter electrode) and (b) cell assembly.
Ohmic drop of each cell set-up. The standard error of the mean estimates the uncertainty associated to the determination of the ohmic drop.
| Electrodes | Mean Ohmic Drop (Ω) | Standard Error |
|---|---|---|
| TF1 | 22.50 | 0.010 |
| TF2 | 16.65 | 0.011 |
| TF3 | 10.09 | 0.012 |
| FF1 | 34.08 | 0.011 |
| FF2 | 18.05 | 0.011 |
| FF3 | 20.02 | 0.013 |
| P1 | 18.29 | 0.011 |
| P2 | 14.05 | 0.010 |
| P3 | 9.81 | 0.012 |
| B1 | 13.71 | 0.009 |
| B2 | 8.16 | 0.010 |
Figure 4Randles-Ševčik plot (a) thick felt (TF); (b) fine felt (FF); (c) paper (P); (d) brush (B).
Electroactive areas.
| Material | Slope | Electroactive Area (cm2) | Electroactive Area per Apparent Surface Area Ratio (EA/AS) |
|---|---|---|---|
| TF1 | 9.44 × 10−2 | 37.16 | 37.2 |
| TF2 | 1.55 × 10−1 | 61.03 | 27.1 |
| TF3 | 3.62 × 10−1 | 142.47 | 35.6 |
| FF1 | 2.47 × 10−2 | 9.73 | 9.73 |
| FF2 | 4.85 × 10−2 | 19.10 | 8.49 |
| FF3 | 7.53 × 10−2 | 29.66 | 7.42 |
| P1 | 4.07 × 10−3 | 1.60 | 1.60 |
| P2 | 3.11 × 10−3 | 1.22 | 0.54 |
| P3 | 3.91 × 10−3 | 1.54 | 0.39 |
| B1 | 5.31 × 10−2 | 20.91 | 11.2 |
| B2 | 1.68 × 10−1 | 65.97 | 12.4 |
Figure 5Linear trend in the logarithmic representation of I vs. υ.
Fractal parameter comparison of different electrodes using CV measurements. The value presented alongside the fractal parameter α represents the 90% confidence intervals for each estimated parameter.
| Electrode | Experimental Range | Fractal Parameter (α) | Correlation Coefficient ( |
|---|---|---|---|
| TF1 | 1–200 | 0.594 ± 0.066 | 0.981 |
| TF2 | 1–200 | 0.580 ± 0.039 | 0.993 |
| TF3 | 1–100 | 0.634 ± 0.052 | 0.992 |
| FF1 | 1–200 | 0.565 ± 0.072 | 0.975 |
| FF2 | 1–200 | 0.600 ± 0.108 | 0.961 |
| FF3 | 1–50 | 0.589 ± 0.066 | 0.989 |
| P1 | 1–200 | 0.464 ± 0.042 | 0.987 |
| P2 | 1–100 | 0.341 ± 0.014 | 0.998 |
| P3 | 2.5–200 | 0.283 ± 0.026 | 0.998 |
| B1 | 1–200 | 0.598 ± 0.056 | 0.986 |
| B2 | 1–200 | 0.547 ± 0.015 | 0.999 |
Figure 6Fractal dimension of the electrodes tested. The values corresponding to Euclidean integer dimensions are shown as red solid lines.
Figure 7Relationship between fractal dimension and EA/AS for each material tested. Black diamond points show the centroids of electrode clusters.