Literature DB >> 28771373

Biomechanical Evaluation of Glenoid Reconstruction With an Implant-Free J-Bone Graft for Anterior Glenoid Bone Loss.

Leo Pauzenberger1,2, Felix Dyrna1,3, Elifho Obopilwe1, Philipp R Heuberer2, Robert A Arciero1, Werner Anderl2, Augustus D Mazzocca1.   

Abstract

BACKGROUND: The anatomic restoration of glenoid morphology with an implant-free J-shaped iliac crest bone graft offers an alternative to currently widely used glenoid reconstruction techniques. No biomechanical data on the J-bone grafting technique are currently available.
PURPOSE: To evaluate (1) glenohumeral contact patterns, (2) graft fixation under cyclic loading, and (3) the initial stabilizing effect of anatomic glenoid reconstruction with the implant-free J-bone grafting technique. STUDY
DESIGN: Controlled laboratory study.
METHODS: Eight fresh-frozen cadaveric shoulders and J-shaped iliac crest bone grafts were used for this study. J-bone grafts were harvested, prepared, and implanted according to a previously described, clinically used technique. Glenohumeral contact patterns were measured using dynamic pressure-sensitive sensors under a compressive load of 440 N with the humerus in (a) 30° of abduction, (b) 30° of abduction and 60° of external rotation, (c) 60° of abduction, and (d) 60° of abduction and 60° of external rotation. Using a custom shoulder-testing system allowing positioning with 6 degrees of freedom, a compressive load of 50 N was applied, and the peak force needed to translate the humeral head 10 mm anteriorly at a rate of 2.0 mm/s was recorded. All tests were performed (1) for the intact glenoid, (2) after the creation of a 30% anterior osseous glenoid defect parallel to the longitudinal axis of the glenoid, and (3) after anatomic glenoid reconstruction with an implant-free J-bone graft. Furthermore, after glenoid reconstruction, each specimen was translated anteriorly for 5 mm at a rate of 4.0 mm/s for a total of 3000 cycles while logging graft protrusion and mediolateral bending motions. Graft micromovements were recorded using 2 high-resolution, linear differential variable reluctance transducer strain gauges placed in line with the long leg of the graft and the mediolateral direction, respectively.
RESULTS: The creation of a 30% glenoid defect significantly decreased glenohumeral contact areas ( P < .05) but significantly increased contact pressures at all abduction and rotation positions ( P < .05). Glenoid reconstruction restored the contact area and contact pressure back to levels of the native glenohumeral joint in all tested positions. The mean (±SD) force to translate the humeral head anteriorly for 10 mm (60° of abduction: 31.7 ± 12.6 N; 60° of abduction and 60° of external rotation: 28.6 ± 7.6 N) was significantly reduced after the creation of a 30% anterior bone glenoid defect (60° of abduction: 12.2 ± 6.8 N; 60° of abduction and 60° of external rotation: 11.4 ± 5.4 N; P < .001). After glenoid reconstruction with a J-bone graft, the mean peak translational force significantly increased (60° of abduction: 85.0 ± 8.2 N; 60° of abduction and 60° of external rotation: 73.6 ± 4.5 N; P < .001) compared with the defect state and baseline. The mean total graft protrusion under cyclical translation of the humeral head over 3000 cycles was 138.3 ± 169.8 µm, whereas the mean maximal mediolateral graft deflection was 320.1 ± 475.7 µm.
CONCLUSION: Implant-free anatomic glenoid reconstruction with the J-bone grafting technique restored near-native glenohumeral contact areas and pressures, provided secure initial graft fixation, and demonstrated excellent osseous glenohumeral stability at time zero. CLINICAL RELEVANCE: The implant-free J-bone graft is a viable alternative to commonly used glenoid reconstruction techniques, providing excellent graft fixation and glenohumeral stability immediately postoperatively. The normalization of glenohumeral contact patterns after reconstruction could potentially avoid the progression of dislocation arthropathy.

Entities:  

Keywords:  J-bone graft; biomechanics; glenoid bone loss; glenoid defect; instability

Mesh:

Year:  2017        PMID: 28771373     DOI: 10.1177/0363546517716927

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  6 in total

1.  Glenoid retroversion is an important factor for humeral head centration and the biomechanics of posterior shoulder stability.

Authors:  Florian B Imhoff; Roland S Camenzind; Elifho Obopilwe; Mark P Cote; Julian Mehl; Knut Beitzel; Andreas B Imhoff; Augustus D Mazzocca; Robert A Arciero; Felix G E Dyrna
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-28       Impact factor: 4.342

2.  Biomechanical Testing of Scapular Spine Autograft for Anterior Glenoid Bone Augmentation.

Authors:  Marcus Mittelsteadt; Bradley J Nelson; Eric M Rohman; Robert A Arciero; Marc A Tompkins
Journal:  Orthop J Sports Med       Date:  2022-05-13

3.  Posterior Open-wedge Osteotomy and Glenoid Concavity Reconstruction Using an Implant-free, J-shaped Iliac Crest Bone Graft in Atraumatic Posterior Instability with Pathologic Glenoid Retroversion and Dysplasia: A Preliminary Report.

Authors:  Lukas Ernstbrunner; Thomas Häller; Manuel Waltenspül; Karl Wieser; Christian Gerber
Journal:  Clin Orthop Relat Res       Date:  2021-09-01       Impact factor: 4.755

4.  Arthroscopic Bone Graft Procedure Combined With Arthroscopic Subscapularis Augmentation for Recurrent Anterior Instability With Glenoid Bone Defect.

Authors:  Raffaele Russo; Marco Maiotti; Ettore Taverna; Cecilia Rao
Journal:  Arthrosc Tech       Date:  2018-05-14

5.  Restoration of the Posterior Glenoid in Recurrent Posterior Shoulder Instability Using an Arthroscopically Placed Iliac Crest Bone Graft: A Computed Tomography-Based Analysis.

Authors:  Roland S Camenzind; Louis Gossing; Javier Martin Becerra; Lukas Ernstbrunner; Julien Serane-Fresnel; Laurent Lafosse
Journal:  Orthop J Sports Med       Date:  2021-01-26

6.  Arthroscopic bone graft procedure combined with arthroscopic subscapularis augmentation (ASA) for recurrent anterior instability with glenoid bone defect: a cadaver study.

Authors:  Raffaele Russo; Marco Maiotti; Ettore Taverna
Journal:  J Exp Orthop       Date:  2018-02-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.