Literature DB >> 28770455

Feasibility of a single-beat prospective ECG-gated cardiac CT for comprehensive evaluation of aortic valve disease using a 256-detector row wide-volume CT scanner: an initial experience.

Jin Young Kim1,2, Young Joo Suh3,4, Suyon Chang1, Dong Jin Im1, Yoo Jin Hong1, Hye-Jeong Lee1, Jin Hur1, Young Jin Kim1, Byoung Wook Choi1.   

Abstract

The aim of our study was to investigate the feasibility of single-beat prospective electrocardiogram (ECG)-gated cardiac computed tomography (CT) using a 256-detector row wide-volume CT scanner for functional and anatomical evaluation of the aortic valve (AV) and coronary arteries in patients with AV disease. A total of 50 patients who underwent cardiac CT scan with a wide-volume 256-detector row CT scanner for the evaluation of AV and aorta were retrospectively enrolled. Cardiac CT was performed using the prospective ECG-gated acquisition mode, and AV image quality was analyzed using a four-point grading system. Severity of aortic stenosis (AS) and aortic regurgitation (AR) were assessed by CT and correlated to that assessed by transthoracic echocardiography (TTE) based on kappa statistics (κ). Estimated radiation exposure was assessed. Among 50 patients, 44 underwent cardiac CT with single-beat acquisition. The median image quality score of AV was 3.0 on the systolic phase and 4.0 on the diastolic phase. Severity of AS and AR by CT showed moderate agreement with TTE. The mean effective radiation dose was 3.75 ± 1.43 mSv for CT angiography. Using 256-detector row wide-volume CT, the single-beat cardiac CT is feasible for evaluation of AV disease and the coronary arteries, with acceptable image quality and a low radiation dose of 3.75 mSv.

Entities:  

Keywords:  Aortic valve; Aortic valve insufficiency; Aortic valve stenosis; Echocardiography; Multidetector computed tomography

Mesh:

Year:  2017        PMID: 28770455     DOI: 10.1007/s10554-017-1223-y

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  24 in total

Review 1.  Aortic stenosis: a contemporary review.

Authors:  Fadi Sawaya; David Liff; Jim Stewart; Stamatios Lerakis; Vasilis Babaliaros
Journal:  Am J Med Sci       Date:  2012-06       Impact factor: 2.378

2.  Radiation dose from single-heartbeat coronary CT angiography performed with a 320-detector row volume scanner.

Authors:  Andrew J Einstein; Carl D Elliston; Andrew E Arai; Marcus Y Chen; Richard Mather; Gregory D N Pearson; Robert L Delapaz; Edward Nickoloff; Ajoy Dutta; David J Brenner
Journal:  Radiology       Date:  2010-03       Impact factor: 11.105

3.  CT and MR imaging of the aortic valve: radiologic-pathologic correlation.

Authors:  Christopher J Bennett; Joseph J Maleszewski; Philip A Araoz
Journal:  Radiographics       Date:  2012 Sep-Oct       Impact factor: 5.333

4.  The effect of a whole heart motion-correction algorithm on CT image quality and measurement reproducibility in Pre-TAVR aortic annulus evaluation.

Authors:  Jeanette Soon; Nada Sulaiman; Jong Kwan Park; Shaw-Hua Anthony Kueh; Christopher Naoum; Darra Murphy; Jennifer Ellis; Cameron J Hague; Philipp Blanke; Jonathon Leipsic
Journal:  J Cardiovasc Comput Tomogr       Date:  2016-08-21

5.  European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 1: aortic and pulmonary regurgitation (native valve disease).

Authors:  Patrizio Lancellotti; Christophe Tribouilloy; Andreas Hagendorff; Luis Moura; Bogdan A Popescu; Eustachio Agricola; Jean-Luc Monin; Luc A Pierard; Luigi Badano; Jose L Zamorano
Journal:  Eur J Echocardiogr       Date:  2010-04

6.  Planimetric measurement of the regurgitant orifice area using multidetector CT for aortic regurgitation: a comparison with the use of echocardiography.

Authors:  Min Hee Jeon; Yeon Hyeon Choe; Soo Jin Cho; Seung Woo Park; Pyo Won Park; Jae K Oh
Journal:  Korean J Radiol       Date:  2010-02-22       Impact factor: 3.500

Review 7.  CT Angiography for the Detection of Coronary Artery Stenoses in Patients Referred for Cardiac Valve Surgery: Systematic Review and Meta-Analysis.

Authors:  Maksymilian P Opolski; Adam D Staruch; Michal Jakubczyk; James K Min; Heidi Gransar; Michal Staruch; Adam Witkowski; Cezary Kepka; Won-Keun Kim; Christian W Hamm; Helge Möllmann; Stephan Achenbach
Journal:  JACC Cardiovasc Imaging       Date:  2016-06-22

8.  Coronary artery disease and its management: influence on survival in patients undergoing aortic valve replacement.

Authors:  C J Mullany; L R Elveback; R L Frye; J R Pluth; W D Edwards; T A Orszulak; L A Nassef; R E Riner; G K Danielson
Journal:  J Am Coll Cardiol       Date:  1987-07       Impact factor: 24.094

9.  Aortic valve area assessment: multidetector CT compared with cine MR imaging and transthoracic and transesophageal echocardiography.

Authors:  Anne-Catherine Pouleur; Jean-Benoît le Polain de Waroux; Agnès Pasquet; Jean-Louis J Vanoverschelde; Bernhard L Gerber
Journal:  Radiology       Date:  2007-07-13       Impact factor: 11.105

10.  Surgical management of aortic valve disease in elderly patients with and without coronary artery disease: influence on quality of life.

Authors:  P A Kurlansky; D B Williams; E A Traad; R G Carrillo; M Zucker; G Ebra
Journal:  J Cardiovasc Surg (Torino)       Date:  2007-04       Impact factor: 1.888