Image quality and radiation dose of CT venography with double dose reduction using model based iterative reconstruction: comparison with conventional CT venography using filtered back projection.

Yeo-Jin Jeong1, Ki Seok Choo1, Kyung Jin Nam1, Ji Won Lee2, Jin You Kim2, Hyuk Jae Jung3, Soo Jin Lim4.   

Abstract

Background Computed tomography venography (CTV) at low kVp using model-based iterative reconstruction (MBIR) can enhance vascular enhancement with noise reduction. Purpose To evaluate image qualities and radiation doses of CTV at 80 kVp using MBIR and a small iodine contrast media (CM) dose and to compare these with those of CTV performed using a conventional protocol. Material and Methods Sixty-five patients (mean age = 58.1 ± 7.2 years) that underwent CTV for the evaluation of deep vein thrombosis (DVT) and varicose veins were enrolled in this study. Patients were divided into two groups: Group A (35 patients, 80 kVp, MBIR, automatic tube current modulation, CM = 270 mg/mL, 100 mL) and Group B (30 patients, 100 kVp, filtered back projection [FBP], 120 fixed mA, CM = 370 mg/mL, 120 mL). Objective and subjective image qualities of inferior vena cava (IVC), femoral vein (FV), and popliteal vein (PV) were assessed and radiation doses were recorded. Results Mean vascular enhancement in group A was significantly lower than in group B ( P < 0.01). Noise in group A was significantly lower than in group B except for PV and contrast-to-noise ratio were not significantly different in the two groups ( P > 0.05). In addition, radiation dose in group A was significantly lower than in group B ( P < 0.001). Subjective image quality comparison revealed group A was statistically inferior to group B except for subjective image noise. Conclusion CTV at 80 kVp using MBIR with small iodine contrast dose provided acceptable image quality at a lower radiation dose than conventional CTV using FBP.

Entities:  

Keywords:  Diagnosis; lower extremity; multidetector computed tomography; radiography; veins

Mesh:

Substances:

Year:  2017        PMID: 28766981     DOI: 10.1177/0284185117725780

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  2 in total

1.  Explore the Value of Dual Source Computer Tomography Automatic Tube Current Regulation in Reducing the Radiation Dose of CTA in Lower Extremity Vessels.

Authors:  Xin Hu; Yi Yu
Journal:  Front Surg       Date:  2022-05-03

2.  Image Quality and Radiation Dose in CT Venography Using Model-Based Iterative Reconstruction at 80 kVp versus Adaptive Statistical Iterative Reconstruction-V at 70 kVp.

Authors:  Chankue Park; Ki Seok Choo; Jin Hyeok Kim; Kyung Jin Nam; Ji Won Lee; Jin You Kim
Journal:  Korean J Radiol       Date:  2019-07       Impact factor: 3.500

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.