Literature DB >> 28766712

Can degradation products released from dental implants affect peri-implant tissues?

M Noronha Oliveira1, W V H Schunemann1, M T Mathew2,3, B Henriques4, R S Magini1, W Teughels5, J C M Souza1,2,4.   

Abstract

This study aimed to assess the literature available on the effects, on peri-implant tissues, of degradation products released from dental implants as a consequence of therapeutic treatment for peri-implantitis and/or of wear-corrosion of titanium. A literature review of the PubMed medline database was performed up to December 31, 2016. The following search terms were used: "titanium wear and dental implant"; "titanium corrosion and dental implant"; "bio-tribocorrosion"; "peri-implantitis"; "treatment of peri-implantitis"; "titanium particles release and dental implant"; and "titanium ion release and dental implant". The keywords were applied to the database in different combinations without limits of time period or type of work. In addition, the reference lists of relevant articles were searched for further studies. Seventy-nine relevant scientific articles on the topic were retrieved. The results showed that pro-inflammatory cytokines, infiltration of inflammatory response cells and activation of the osteoclasts activity are stimulated in peri-implant tissues in the presence of metal particles and ions. Moreover, degenerative changes were reported in macrophages and neutrophils that phagocytosed titanium microparticles, and mutations occurred in human cells cultured in medium containing titanium-based nanoparticles. Debris released from the degradation of dental implants has cytotoxic and genotoxic potential for peri-implant tissues. Thus, the amount and physicochemical properties of the degradation products determine the magnitude of the detrimental effect on peri-implant tissues.
© 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  bio-tribocorrosion; debris; peri-implantitis; titanium ions; wear

Mesh:

Substances:

Year:  2017        PMID: 28766712     DOI: 10.1111/jre.12479

Source DB:  PubMed          Journal:  J Periodontal Res        ISSN: 0022-3484            Impact factor:   4.419


  35 in total

Review 1.  The influence of zirconia veneer thickness on the degree of conversion of resin-matrix cements: an integrative review.

Authors:  Christie M Tafur-Zelada; Oscar Carvalho; Filipe S Silva; Bruno Henriques; Mutlu Özcan; Júlio C M Souza
Journal:  Clin Oral Investig       Date:  2021-03-30       Impact factor: 3.573

Review 2.  Removal of osseointegrated dental implants: a systematic review of explantation techniques.

Authors:  Margaux Roy; Lucie Loutan; Giovanni Garavaglia; Dena Hashim
Journal:  Clin Oral Investig       Date:  2019-11-15       Impact factor: 3.573

3.  Effect of the Size of Titanium Particles Released from Dental Implants on Immunological Response.

Authors:  Juan Antonio Callejas; Javier Gil; Aritza Brizuela; Román A Pérez; Begoña M Bosch
Journal:  Int J Mol Sci       Date:  2022-06-30       Impact factor: 6.208

Review 4.  Cytotoxic effects of submicron- and nano-scale titanium debris released from dental implants: an integrative review.

Authors:  Redouane Messous; Bruno Henriques; Hassan Bousbaa; Filipe S Silva; Wim Teughels; Júlio C M Souza
Journal:  Clin Oral Investig       Date:  2021-02-22       Impact factor: 3.573

5.  Physicochemical and microscopic characterization of implant-abutment joints.

Authors:  Patricia A Lopes; Adriana F P Carreiro; Rubens M Nascimento; Brendan R Vahey; Bruno Henriques; Júlio C M Souza
Journal:  Eur J Dent       Date:  2018 Jan-Mar

6.  Potential Causes of Titanium Particle and Ion Release in Implant Dentistry: A Systematic Review.

Authors:  Rafael Delgado-Ruiz; Georgios Romanos
Journal:  Int J Mol Sci       Date:  2018-11-13       Impact factor: 5.923

Review 7.  Etiology and Measurement of Peri-Implant Crestal Bone Loss (CBL).

Authors:  Adrien Naveau; Kouhei Shinmyouzu; Colman Moore; Limor Avivi-Arber; Jesse Jokerst; Sreenivas Koka
Journal:  J Clin Med       Date:  2019-02-01       Impact factor: 4.241

8.  Salivary Levels of Titanium, Nickel, Vanadium, and Arsenic in Patients Treated with Dental Implants: A Case-Control Study.

Authors:  Piero Papi; Andrea Raco; Nicola Pranno; Bianca Di Murro; Pier Carmine Passarelli; Antonio D'Addona; Giorgio Pompa; Maurizio Barbieri
Journal:  J Clin Med       Date:  2020-04-27       Impact factor: 4.241

9.  Determinants of corrosion resistance of Ti-6Al-4V alloy dental implants in an In Vitro model of peri-implant inflammation.

Authors:  Larissa O Berbel; Everson do P Banczek; Ioannis K Karoussis; Georgios A Kotsakis; Isolda Costa
Journal:  PLoS One       Date:  2019-01-31       Impact factor: 3.240

10.  A Literature Review Study on Atomic Ions Dissolution of Titanium and Its Alloys in Implant Dentistry.

Authors:  Sammy Noumbissi; Antonio Scarano; Saurabh Gupta
Journal:  Materials (Basel)       Date:  2019-01-24       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.