Maximal Aortic Valve Cusp Separation and Severity of Aortic Stenosis.

K Jayaprakash1, V P Dilu2, Raju George3.   

Abstract

INTRODUCTION: An integrated approach that incorporates two dimensional, M mode and Doppler echocardiographic evaluation has become the standard means for accurate quantification of severity of valvular aortic stenosis. Maximal separation of the aortic valve cusps during systole has been shown to correlate well with the severity of aortic stenosis measured by other echocardiographic parameters. AIM: To study the correlation between Maximal Aortic valve Cusp Separation (MACS) and severity of aortic valve stenosis and to find cut-off values of MACS for detecting severe and mild aortic stenosis.
MATERIALS AND METHODS: In the present prospective observational study, we have compared the accuracy of MACS distance and the aortic valve area calculated by continuity equation in 59 patients with varying degrees of aortic valve stenosis. Aortic leaflet separation in M mode was identified as the distance between the inner edges of the tips of these structures at mid systole in the parasternal long axis view. Cuspal separation was also measured in 2D echocardiography from the parasternal long axis view and the average of the two values was taken as the MACS. Patients were grouped into mild, moderate and severe aortic stenosis based on the aortic valve area calculated by continuity equation. The resultant data regarding maximal leaflet separation on cross-sectional echocardiogram was then subjected to linear regression analysis in regard to correlation with the peak transvalvular aortic gradient as well as the calculated aortic valve area. A cut-off value for each group was derived using ROC curve.
RESULTS: There was a strong correlation between MACS and aortic valve area measured by continuity equation and the peak and mean transvalvular aortic gradients. Mean MACS was 6.89 mm in severe aortic stenosis, 9.97 mm in moderate aortic stenosis and 12.36 mm in mild aortic stenosis. MACS below 8.25 mm reliably predicted severe aortic stenosis, with high sensitivity, specificity and positive predictive value. MACS above 11.25 mm practically ruled out significant aortic stenosis.
CONCLUSION: Measurement of MACS is a simple echocardio-graphic method to assess the severity of valvular aortic stenosis, with high sensitivity and specificity. MACS can be extremely useful in two clinical situations as a simple screening tool for assessment of stenosis severity and also helps in decision making non invasively when there is discordance between the other echocardiographic parameters of severity of aortic stenosis.

Entities:  

Keywords:  Aortic valve stenosis; Continuity equation; Echocardiography

Year:  2017        PMID: 28764221      PMCID: PMC5535413          DOI: 10.7860/JCDR/2017/27147.10045

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  11 in total

1.  Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice.

Authors:  Helmut Baumgartner; Judy Hung; Javier Bermejo; John B Chambers; Arturo Evangelista; Brian P Griffin; Bernard Iung; Catherine M Otto; Patricia A Pellikka; Miguel Quiñones
Journal:  J Am Soc Echocardiogr       Date:  2009-01       Impact factor: 5.251

2.  Frequency by decades of unicuspid, bicuspid, and tricuspid aortic valves in adults having isolated aortic valve replacement for aortic stenosis, with or without associated aortic regurgitation.

Authors:  William C Roberts; Jong M Ko
Journal:  Circulation       Date:  2005-02-14       Impact factor: 29.690

Review 3.  The global burden of aortic stenosis.

Authors:  Jeremy J Thaden; Vuyisile T Nkomo; Maurice Enriquez-Sarano
Journal:  Prog Cardiovasc Dis       Date:  2014-03-02       Impact factor: 8.194

4.  Correlation between echocardiography and cardiac catheterization in assessing the severity of aortic stenosis.

Authors:  M Motro; Z Vered; S Rath; A Schneeweiss; H N Neufeld
Journal:  Eur Heart J       Date:  1983-02       Impact factor: 29.983

5.  Value and limitations of cross-sectional echocardiography of the aortic valve in the diagnosis and quantification of valvular aortic stenosis.

Authors:  A N DeMaria; W Bommer; J Joye; G Lee; J Bouteller; D T Mason
Journal:  Circulation       Date:  1980-08       Impact factor: 29.690

6.  Aortic root dilatation in young men with normally functioning bicuspid aortic valves.

Authors:  S Nistri; M D Sorbo; M Marin; M Palisi; R Scognamiglio; G Thiene
Journal:  Heart       Date:  1999-07       Impact factor: 5.994

7.  Usefulness of bicuspid aortic valve phenotype to predict elastic properties of the ascending aorta.

Authors:  Benjamin M Schaefer; Mark B Lewin; Karen K Stout; Peter H Byers; Catherine M Otto
Journal:  Am J Cardiol       Date:  2007-01-05       Impact factor: 2.778

8.  Cross-sectional echocardiography in assessing the severity of valvular aortic stenosis.

Authors:  A E Weyman; H Feigebaum; J C Dillon; S Chang
Journal:  Circulation       Date:  1975-11       Impact factor: 29.690

Review 9.  Aortic stenosis.

Authors:  John B Chambers
Journal:  Eur J Echocardiogr       Date:  2009-01

10.  Aortic stenosis: echocardiographic cusp separation and surgical description of aortic valve in 22 patients.

Authors:  S Chang; S Clements; J Chang
Journal:  Am J Cardiol       Date:  1977-04       Impact factor: 2.778

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.