Literature DB >> 28763784

Liposome-amplified photoelectrochemical immunoassay for highly sensitive monitoring of disease biomarkers based on a split-type strategy.

Junyang Zhuang1, Bin Han2, Wenchao Liu3, Jinfei Zhou3, Kewei Liu3, Dapeng Yang4, Dianping Tang5.   

Abstract

Liposomes are an excellent candidate component for biosensors to transduce and amplify detection signals due to their outstanding ability in encapsulating signal marker compounds. However, the use of liposomes for photoelectrochemical (PEC) signal transduction has not yet been achieved due the lack of appropriate sensing strategy. Herein, we report on a novel liposomes-amplified PEC immunoassay (LAPIA) method for sensitive HIV-p24 antigen (p24) detection based on a split-type strategy. Initially, liposomes were encapsulated with alkaline phosphatase (ALP) in their hydrophilic chamber and conjugated with secondary antibody on the surface to form the ALP-encapsulated liposomes (ALP-Ls) based PEC signal label. Sandwiched immunoassay based on the ALP-Ls label was then carried out in microwell plate. Upon addition of tween 20, the ALP molecules were released and catalyzed the hydrolysis of ascorbic acid 2-phosphate (AA-p) to produce ascorbic acid (AA). The latter then donated electron to the graphene/g-C3N4 nanohybrids based photoelectrode, arousing an increased photocurrent signal. The separation of immunoreaction step and PEC signal excitation (i.e. split-type) not only enabled the realization of liposomes based amplification strategy, but also could eliminate the PEC-caused biomolecules damage. The developed PEC method possessed a wide calibration range from 1.0pgmL-1 to 50ngmL-1 and a low detection limit of 0.63pgmL-1. Its practicability was demonstrated by assaying human serum samples. Moreover, the universality of the liposomes-amplified PEC sensing strategy was also demonstrated by developing it into a sensitive microRNA detection method.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  HIV-p24 antigen; Liposome; Photoelectrochemical immunoassay; Split-type detection

Mesh:

Substances:

Year:  2017        PMID: 28763784     DOI: 10.1016/j.bios.2017.07.067

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  A versatile and ultrasensitive molecularly imprinted electrochemiluminescence sensor with HRP-encapsulated liposome labeled by light-triggered click reaction for pesticide residues.

Authors:  Guangyan Liu; Shiyu Li; Zejun Jiang; Jianping Li
Journal:  Mikrochim Acta       Date:  2021-12-21       Impact factor: 5.833

2.  Liposome-coated mesoporous silica nanoparticles loaded with L-cysteine for photoelectrochemical immunoassay of aflatoxin B1.

Authors:  Youxiu Lin; Qian Zhou; Yongyi Zeng; Dianping Tang
Journal:  Mikrochim Acta       Date:  2018-06-02       Impact factor: 5.833

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.