| Literature DB >> 28763622 |
Xun Chen1, Steven Stout1, Uwe Mueller1, George Boykow1, Richard Visconti1, Phieng Siliphaivanh1, Kerrie Spencer1, Jeremy Presland1, Michael Kavana1, Andrea D Basso1, David G McLaren1, Robert W Myers1.
Abstract
We have developed and validated label-free, liquid chromatography-mass spectrometry (LC-MS)-based equilibrium direct and competition binding assays to quantitate small-molecule antagonist binding to recombinant human and mouse BLT1 receptors expressed in HEK 293 cell membranes. Procedurally, these binding assays involve (1) equilibration of the BLT1 receptor and probe ligand, with or without a competitor; (2) vacuum filtration through cationic glass fiber filters to separate receptor-bound from free probe ligand; and (3) LC-MS analysis in selected reaction monitoring mode for bound probe ligand quantitation. Two novel, optimized probe ligands, compounds 1 and 2, were identified by screening 20 unlabeled BLT1 antagonists for direct binding. Saturation direct binding studies confirmed the high affinity, and dissociation studies established the rapid binding kinetics of probe ligands 1 and 2. Competition binding assays were established using both probe ligands, and the affinities of structurally diverse BLT1 antagonists were measured. Both binding assay formats can be executed with high specificity and sensitivity and moderate throughput (96-well plate format) using these approaches. This highly versatile, label-free method for studying ligand binding to membrane-associated receptors should find broad application as an alternative to traditional methods using labeled ligands.Entities:
Keywords: BLT1; LC-MS; LTB4; binding; label-free
Year: 2017 PMID: 28763622 DOI: 10.1177/2472555217719748
Source DB: PubMed Journal: SLAS Discov ISSN: 2472-5552 Impact factor: 3.341